2022
DOI: 10.1016/j.buildenv.2022.109465
|View full text |Cite
|
Sign up to set email alerts
|

Optimization study of heating performance for an impinging jet ventilation system based on data-driven model coupled with TOPSIS method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 45 publications
0
3
0
Order By: Relevance
“…2). where it is possible to visually determine the sections of the network with high and low pressure, the most dangerous from the point of view of leaks, and, consequently, reducing the aerodynamic efficiency and energy efficiency of the ventilation system [8][9][10].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…2). where it is possible to visually determine the sections of the network with high and low pressure, the most dangerous from the point of view of leaks, and, consequently, reducing the aerodynamic efficiency and energy efficiency of the ventilation system [8][9][10].…”
Section: Discussionmentioning
confidence: 99%
“…Figure3shows a diagram of the pressure in the flow of the duct ventilation valve, where it is possible to visually determine the sections of the network with high and low pressure, the most dangerous from the point of view of leaks, and, consequently, reducing the aerodynamic efficiency and energy efficiency of the ventilation system[8][9][10].To increase the aerodynamic efficiency and the complex energy parameter of the ventilation system, it is necessary to eliminate volume losses by increasing the reliability of ventilation equipment, in particular, ventilation valves for various purposes.The expression for the complex energy parameter of the ventilation system EPVS can be written as…”
mentioning
confidence: 99%
“…To solve these problems, this research group put forward a new air supply mode for a powerhouse in the tall space of an underground hydropower station combined with a vertical wall-attached air supply mode. Recently, jet ventilation has gained scholarly attention due to high momentum and favorable flow pattern [21][22][23], including impinging jet ventilation [24,25], attached plane jets, confluent jet ventilation and so on [26][27][28]. Compared with other air supply methods, the total cooling load borne by an attached air supply is smaller, which saves energy and does not affect the net height of a space.…”
Section: Introductionmentioning
confidence: 99%