1991
DOI: 10.1016/0021-9673(91)80068-r
|View full text |Cite
|
Sign up to set email alerts
|

Optimization and evaluation of the performance of arrangements for UV detection in high-resolution separations using fused-silica capillaries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
45
0

Year Published

1995
1995
2001
2001

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 83 publications
(49 citation statements)
references
References 23 publications
1
45
0
Order By: Relevance
“…Consequently, limits of detection are about 25-50 times lower compared to on-column detection. For instance, the limit of detection for uracil with on-column detection was 3.1.10 -6 mol 1-], and with the longitudinal flow cell it was equal to 9.8" 10 -8 mol 1-t [ 138]. The contribution of longitudinal flow cells to extracolumn band broadening, i.e.…”
Section: Uv Absorbance Detectionmentioning
confidence: 97%
See 2 more Smart Citations
“…Consequently, limits of detection are about 25-50 times lower compared to on-column detection. For instance, the limit of detection for uracil with on-column detection was 3.1.10 -6 mol 1-], and with the longitudinal flow cell it was equal to 9.8" 10 -8 mol 1-t [ 138]. The contribution of longitudinal flow cells to extracolumn band broadening, i.e.…”
Section: Uv Absorbance Detectionmentioning
confidence: 97%
“…Limits of detection reported for on-column detection are typically around 1-5.10 6 mol 1-J for compounds such as uracil, cytosine and thymine, with a 100 I~m I.D. flow cell [138]. Despite the extremely small path lengths, detection is feasible at the sub-ng level.…”
Section: Uv Absorbance Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…The pressure was monitored with a digital pressure sensor (Type 4041A200; Kistler, Winterthur, Switzerland) combined with a current amplifier (Type 4061; Kistler) and a recorder (Model BDlll; Kipp & Zonen, Delft, Netherlands). Two on-column detection systems were employed, a UV absorbance detector (Kratos Model 757) using a laboratory-built on-column detection cell with adjustable slit [6] (the detector rise time was set to 0.1 s) and a heliumcadmium laser ()rex = 325 nm) (Model 356 XM; Omnichrome, Chino, CA, USA) used as a light source for laser-induced fluorescence detection (LIF) with emission wavelength set at 380 nm. The fluorescence yield was measured with a…”
Section: Apparatusmentioning
confidence: 99%
“…On-column UV-detection is most commonly used in CZE. One of the main restrictions is the high detection limit, in the 10-5-10-6 mol/1 range [3], as a result of the short available light path, the inner diameter of the capillary. Capillaries with diameters of 10-100 gm I.D.…”
Section: Introductionmentioning
confidence: 99%