2008
DOI: 10.1016/j.aca.2008.01.083
|View full text |Cite
|
Sign up to set email alerts
|

Optimising cell temperature and dispersion field strength for the screening for putrescine and cadaverine with thermal desorption-gas chromatography–differential mobility spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 24 publications
(17 citation statements)
references
References 21 publications
0
16
0
1
Order By: Relevance
“…Biogenic amines are usually determined by thin layer chromatography (TLC) [6,7], capillary electrophoresis (CE) [8][9][10], gas chromatography (GC) [11,12] and liquid chromatography (LC) with ultra-violet (UV) or fluorescence detection [13][14][15][16][17][18][19][20][21][22][23]25]. Among these methods, LC is the most popular and frequently used for the separation and quantification of biogenic amines.…”
Section: Introductionmentioning
confidence: 99%
“…Biogenic amines are usually determined by thin layer chromatography (TLC) [6,7], capillary electrophoresis (CE) [8][9][10], gas chromatography (GC) [11,12] and liquid chromatography (LC) with ultra-violet (UV) or fluorescence detection [13][14][15][16][17][18][19][20][21][22][23]25]. Among these methods, LC is the most popular and frequently used for the separation and quantification of biogenic amines.…”
Section: Introductionmentioning
confidence: 99%
“…Biogenic amines are usually determined by separation techniques like thin layer chromatography (TLC) [22][23][24], capillary electrophoresis (CE) [17,[25][26][27][28][29], gas chromatography (GC) [30][31][32][33][34] and High performance liquid chromatography (HPLC) [21,[35][36][37][38][39][40][41][42][43][44][45][46][47][48][49]. HPLC is the technique most extensively used due to its high resolution, sensitivity, great versatility, and simple sample treatment.…”
Section: Introductionmentioning
confidence: 99%
“…Data were generated from a central composite design 161 (CCD) with each of the 4 factors at 4 levels with replicates at five different 162 concentrations, see Table 2 [15]. The DMS parameters were optimised for 163 maximum sensitivity while maintaining "satisfactory" resolution between the ion 164 clusters generated within the 63 Ni ionisation source see Table 3, and Figures 2, 3 165 and 4.…”
Section: Experimental 93mentioning
confidence: 99%