2006 International Conference on Power System Technology 2006
DOI: 10.1109/icpst.2006.321926
|View full text |Cite
|
Sign up to set email alerts
|

Optimal SVC and TCSC Placement for Minimization of Transmission Losses

Abstract: Proper placement of Static VAR compensator (SVC) and Thyristor Controlled Series compensator (TCSC) reduces transmission losses, increases the available capacity, and improves the voltage profile. This paper presents an optimal placement of SVC and TCSC to determine SVC and TCSC locations and control parameters for minimization of transmission loss. Optimal location method utilizes the sensitivity of total real power transmission loss with respect to the control parameters of devices and multiply with new equa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 4 publications
(5 reference statements)
0
14
0
Order By: Relevance
“…The TCSC devices are optimally placed in the transmission line for distributing the powers in the network [17][18][19][20][21]. AbdelMooamen [17] presented a paper on optimal power flow incorporates single/multi TCSC devices using spare Newton's algorithms.…”
Section: Loss Sensitivity Analysismentioning
confidence: 99%
“…The TCSC devices are optimally placed in the transmission line for distributing the powers in the network [17][18][19][20][21]. AbdelMooamen [17] presented a paper on optimal power flow incorporates single/multi TCSC devices using spare Newton's algorithms.…”
Section: Loss Sensitivity Analysismentioning
confidence: 99%
“…Insertion of FACTS devices is found to be highly effective in preventing voltage instability and minimize the active or real power loss on transmission lines [11,12]. Series and shunt 2 Advances in Electrical Engineering compensating devices are used to enhance the static voltage stability margin and reduce the real power loss appreciably [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…The power flow P ab through the transmission line l is a function of line impedance X ab , the voltage magnitude V a , V b and the phase angle between the sending and receiving end voltage (δ a -δ b ) [1]. …”
Section: Transmission Loss Minimizationmentioning
confidence: 99%
“…Fitness is computed for each particle. Determine the P best 1 and G best 1 value and it is stored in ascending order for the purpose of minimization of loss. P best_1 = min(x 1 ,… x n )_old and Fitness 1= Loss min_1.…”
Section: Evolutionary Particle Swarm Optimizationmentioning
confidence: 99%