2015
DOI: 10.1016/j.energy.2015.02.092
|View full text |Cite
|
Sign up to set email alerts
|

Optimal pulse current shape for transient supercooling of thermoelectric cooler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(10 citation statements)
references
References 35 publications
0
8
0
2
Order By: Relevance
“…If the time term in Formula (1) is 0, the steady state heat absorption can be obtained as follows: The governing equation of the integrated thermoelectric generation-cooling system is [18,19]:…”
Section: Theoretical Modelmentioning
confidence: 99%
“…If the time term in Formula (1) is 0, the steady state heat absorption can be obtained as follows: The governing equation of the integrated thermoelectric generation-cooling system is [18,19]:…”
Section: Theoretical Modelmentioning
confidence: 99%
“…Використання наближених математичних моделей ПНТО дає змогу отримати результат, зокрема залежність ISSN 2226-3780 температури охолодження від часу, в аналітичній формі, як для випадку постійного струму [13], так і для окремих функцій, які задають залежність струму від часу, наприклад, для прямокутних або синусоїдальних імпульсів струму [16]. Але для розв'язування задач, пов'язаних з оптимізацією нестаціонарного процесу охолодження, навіть у випадку найпростіших математичних моделей, які описують процес, вже доводиться використовувати комп'ютерні методи [18][19][20][21][22][23].…”
Section: аналіз літературних даних та постановка проблемиunclassified
“…математична модель пнто. Огляд та аналіз наукових праць, які стосуються теоретичного опису нестаціонарного термоелектричного охолодження [5][6][7][8][9][10][13][14][15][16][17][18][19][20][21][22][23], приводять до висновку, що математична модель ПНТО повинна враховувати наступні важливі фізичні фактори:…”
Section: оптимізація нестаціонарного процесу термоелектричного охолодunclassified
“…Further improvements could be gained by modeling the Joule heat generated within the solder and copper as well as radiative and convective losses. 27 To produce a model that accurately reproduces the transient effect from experimental data with intrinsic properties, these items must be included and / or provided in the experimental technical paper that provides experimental data. To simplify reporting, sometimes, T h is measured and reported vs. time and then imposed on the model.…”
Section: T Rmentioning
confidence: 99%
“…19 Variables that affect pulsed Peltier cooling include: thermoelement length, 15 current pulse amplitude 15,19 pulse duration, 19 pulse shape, 14,16,19,[22][23][24][25][26][27] time between pulses, 28 thermoelectric figure of merit, 15 thermoelement thermal diffusivity 15 , thermoelement shape [29][30][31] and the number of stages of a multi-stage thermoelectric cooler. 32 Of these variables, there are only two that can be varied to change the operating conditions for any given pulse shape.…”
mentioning
confidence: 99%