2014
DOI: 10.2749/222137814814027567
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Placement of Viscous Dampers in Super Tall Buildings Based on Grid Shear Velocity

Abstract: <p> Due to its excellent lateral stiffness and space flexibility, the frame-core wall structures are widely applied in super high-rise buildings. Energy dissipation technology can be applied in tall buildings to reduce the seismic responses of main structures and realize optimal structural design for the main structure. As an effective energy dissipation device, viscous damper can generate damping force by viscosity effects of the viscous liquid. Due to its velocity-dependent nature, viscous dampers can … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…To analyze the seismic effect in a VD system, we usually define an additional damping ratio provided by the VD using the nonlinear time history analysis method to describe its nonlinearity; this allows us to evaluate the effect of the VD on the structure. Then we use the mode decomposition response spectrum method to evaluate and optimize the main structure, which helps realize the equipment design and decouple the main structure design, improving design efficiency . The virtual VD model of additional damping proposed in this paper is developed based on this idea.…”
Section: Optimal Design Of Vdsmentioning
confidence: 99%
See 1 more Smart Citation
“…To analyze the seismic effect in a VD system, we usually define an additional damping ratio provided by the VD using the nonlinear time history analysis method to describe its nonlinearity; this allows us to evaluate the effect of the VD on the structure. Then we use the mode decomposition response spectrum method to evaluate and optimize the main structure, which helps realize the equipment design and decouple the main structure design, improving design efficiency . The virtual VD model of additional damping proposed in this paper is developed based on this idea.…”
Section: Optimal Design Of Vdsmentioning
confidence: 99%
“…Then we use the mode decomposition response spectrum method to evaluate and optimize the main structure, which helps realize the equipment design and decouple the main structure design, improving design efficiency. [10] The virtual VD model of additional damping proposed in this paper is developed based on this idea.…”
Section: Virtual Vd Modelmentioning
confidence: 99%