Optimal Location of STATCOM and SVC Based on Contingency Voltage Stability by Using Continuation Power Flow: Case Studies of Khouzestan Power Networks in Iran

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
1
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 6 publications
0
4
0
1
Order By: Relevance
“…Simulation results on IEEE 6-bus has been confirmed that the SVC gives the best voltage profile and transmission loss compared to TCSC. Similarly, to enhance voltage stability system under contingency conditions, Farbod Larki et al [192] have been explored the PFC strategy based on MLP and its corresponding Mega Watt Margin (MWM) decrease percent in each contingency by selecting the suitable placements of FACTS controllers like SVC, TCSC and STATCOM. From obtained results for Khouzestan power network, Tt can be concluded that the STATCOM device provide higher voltage stability margin than SVC at weakest bus.…”
Section: Summary Of Sensitive Index Methods Related To Facts Devices ...mentioning
confidence: 99%
“…Simulation results on IEEE 6-bus has been confirmed that the SVC gives the best voltage profile and transmission loss compared to TCSC. Similarly, to enhance voltage stability system under contingency conditions, Farbod Larki et al [192] have been explored the PFC strategy based on MLP and its corresponding Mega Watt Margin (MWM) decrease percent in each contingency by selecting the suitable placements of FACTS controllers like SVC, TCSC and STATCOM. From obtained results for Khouzestan power network, Tt can be concluded that the STATCOM device provide higher voltage stability margin than SVC at weakest bus.…”
Section: Summary Of Sensitive Index Methods Related To Facts Devices ...mentioning
confidence: 99%
“…Y u Liu Bhattacharya, S. et al [13] have designed a controller in which an optimal combination modulation strategy is used, which leads to some challenges in designing the controller, such as extra switching and the balancing of individual dc capacitor voltages. Larki, F. et al [14] have presented a new approach PROCEEDINGS OF ICETECT 2011 978-1-4244-7926-9/11/$26.00 ©2011 IEEE for identification of optimal locations of STATCOM and SVC and also simulated case studies conducted on Kouzestan power networks in Iran based on the proposed techniques. Albasri, F.A.et al [15] have investigated a comparative study of the performance of distance relays for transmission lines compensated by shunt connected flexible ac transmission system (FACTS) controllers.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, this goal implicitly expresses that a rapid change of power transmission path should be possible in the case of event occurrence so that the power transmission can be done desirably in the whole transmission system. Fulfilling the two abovementioned goals demand the improvement of controllers and high-power compensators [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…In [6], a novel method has been proposed for detecting the optimal location of STATCOM and static var compensator (SVC). The power system which operates in a stability boundary lost its stability by occurring disturbance.…”
Section: Introductionmentioning