2013 IEEE International Conference of IEEE Region 10 (TENCON 2013) 2013
DOI: 10.1109/tencon.2013.6718508
|View full text |Cite
|
Sign up to set email alerts
|

Optimal design of isolated microgrid considering run-time load controllability

Abstract: In this work, an optimal design framework for the isolated microgrid system is presented, which contains two-level optimization for the configuration and operation of both the distributed renewable resources (DRR) and controllable loads. The controllability of special loads is discussed and modeled by the investment cost function and simplified utilization strategy. Moreover, a particle swarm optimization (PSO) algorithm is used for the solution of the proposed optimal design problem. Test results for an isola… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 9 publications
(7 reference statements)
0
3
0
Order By: Relevance
“…Optimization Algorithm. Considering the complexity of the optimization problem, a particle swarm optimization algorithm is adopted to calculate the optimal MCR capacity [11], and the flowchart is shown in Fig. 1.…”
Section: Methodsmentioning
confidence: 99%
“…Optimization Algorithm. Considering the complexity of the optimization problem, a particle swarm optimization algorithm is adopted to calculate the optimal MCR capacity [11], and the flowchart is shown in Fig. 1.…”
Section: Methodsmentioning
confidence: 99%
“…Likewise, a two-level planning framework considering load controllability is proposed in [75]. The planning problem objective was to maximize microgrid annual profit.…”
Section: Framework On Microgrid Planning Considering Drmentioning
confidence: 99%
“…The second stage determines the dispatch strategy using mixed-integer linear programming (MILP), where the microgrid operation is nested into planning. The same idea is also used in [9,10]. The two-stage model combines capacity configuration optimisation and microgrid operation optimisation together, which describes microgrid planning clearly.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Microgrid scheduling is studied in [23], where the microgrid is assumed to be equipped with smart appliances to make the load shiftable. In [10], a simple controllable load model is considered in microgrid optimal design, where controllable load is switched off and on as needed. Heating/cooling systems are included in microgrid planning in [24], which are controllable to some extent.…”
Section: Introductionmentioning
confidence: 99%