Optimal allocation of multi-type FACTS devices in power systems based on power flow entropy

Abstract: Flexible AC transmission systems (FACTS) devices can effectively optimize the distribution of power flow. Power flow entropy can be applied as a measure of load distribution. In this paper, a method is proposed to optimize the distribution of power flow with the coordination of multi-type FACTS devices and establishes the corresponding mathematical models. The modified group searcher optimization (GSO) algorithm is proposed, in which the angle search is combined with chaotic search model to avoid jumping into … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 26 publications
0
20
0
Order By: Relevance
“…In addition, the series MMC interfaces to the power grid through the series transformer. The power flow of the transmission line can be regulated by adjusting the magnitude and phase angle of the voltage injected by series MMC [1,2].…”
Section: Mmc-upfc Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, the series MMC interfaces to the power grid through the series transformer. The power flow of the transmission line can be regulated by adjusting the magnitude and phase angle of the voltage injected by series MMC [1,2].…”
Section: Mmc-upfc Modelmentioning
confidence: 99%
“…Consequently, the output voltage would increase. At every switch cycle, the numbers of SMs which are put into operation in the upper and lower arms can be determined according to (1).…”
Section: Basic Principle Of Nlmmentioning
confidence: 99%
See 1 more Smart Citation
“…Bridge-type fault current limiter (BFCL) that uses a switched transformer-type DC reactor, whilst the load current exceeds a predefined threshold, the secondary side of the transformer can be opened by an insulated gate bipolar transistor [18]. These FACTS type devices have possible capability of being applied for fault current suppression, because they can perform power flow regulation functions under steadystate operation conditions [19], and can also be switched to an emergency control status during serious faults. Thyristor-controlled phase shifting transformer (TCPST) is a special FACTS device with a series and a parallel power transformer, which fulfills fast phase angle adjustment of the voltage across the device to regulate regional power flow [20][21][22].…”
Section: Introductionmentioning
confidence: 99%
“…Much work has been done in the field of evaluation methods. In [8][9][10][11][12][13][14], the analytic hierarchy process (AHP) method [8], fuzzy AHP method [9][10][11][12], and entropy method [13,14] were studied. Interval arithmetic (IA) is an efficient tool for handling ''unknown but bounded'' uncertainties.…”
Section: Introductionmentioning