Optics for EUV, X-Ray, and Gamma-Ray Astronomy VIII 2017
DOI: 10.1117/12.2274905
|View full text |Cite
|
Sign up to set email alerts
|

Optical simulations for design, alignment, and performance prediction of silicon pore optics for the ATHENA x-ray telescope

Abstract: The ATHENA X-ray observatory is a large-class ESA approved mission, with launch scheduled in 2028. The technology of silicon pore optics (SPO) was selected as baseline to assemble ATHENA's optic with hundreds of mirror modules, obtained by stacking wedged and ribbed silicon wafer plates onto silicon mandrels to form the Wolter-I configuration. In the current configuration, the optical assembly has a 3 m diameter and a 2 m 2 effective area at 1 keV, with a required angular resolution of 5 arcsec. The angular re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(15 citation statements)
references
References 24 publications
0
15
0
Order By: Relevance
“…These are adapted to conform with the needs and the status of the development of the different optics. Before the tests take place input from simulations [14] and if available measurements taken at other beamlines (i.e. BESSY) are used to prepare and optimize the measurement plan.…”
Section: Measurementsmentioning
confidence: 99%
“…These are adapted to conform with the needs and the status of the development of the different optics. Before the tests take place input from simulations [14] and if available measurements taken at other beamlines (i.e. BESSY) are used to prepare and optimize the measurement plan.…”
Section: Measurementsmentioning
confidence: 99%
“…Finally, also the invariance of the PSF centroids positions of X-ray and UV images, even in presence of profiles longitudinal errors, was already presented one year ago. 8 That confirmed that an integration process based on UV illumination is well suitable for SPOs to achieve the requested alignment accuracy.…”
Section: Diffraction Effect Of Multiple Mirror Modulesmentioning
confidence: 59%
“…The effective area of ATHENA can be calculated by means of the IDL code presented in previous papers. 7,8 The code is based on the analytical computation of the illuminated area of each pore, extended to the full optical system. The code takes the following input information:…”
Section: Effective Area Simulationmentioning
confidence: 99%
See 2 more Smart Citations