2018
DOI: 10.1186/s12886-018-0976-y
|View full text |Cite
|
Sign up to set email alerts
|

Optical coherence tomography angiography of the macula and optic nerve head: microvascular density and test-retest repeatability in normal subjects

Abstract: BackgroundDespite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements.MethodsCross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(10 citation statements)
references
References 30 publications
(41 reference statements)
1
9
0
Order By: Relevance
“…However, choroidal vascular structures were evaluated only using layer analysis due to the lack of measurement technology, and autonomic regulation is quite limited in this region. In contrast, we used OCT with split-spectrum angiography to analyze the vascular plexus of the retina and the optic nerve head by measuring the intravascular distribution of erythrocytes without the use of tracers or radiation (21,22) . These OCTA measures disclosed greater ONH-BFA values in patients with FMS, in contrast to those reported by several previous studies, as well as a weak correlation between ONH-BFA and increased disease severity.…”
Section: Discussionmentioning
confidence: 99%
“…However, choroidal vascular structures were evaluated only using layer analysis due to the lack of measurement technology, and autonomic regulation is quite limited in this region. In contrast, we used OCT with split-spectrum angiography to analyze the vascular plexus of the retina and the optic nerve head by measuring the intravascular distribution of erythrocytes without the use of tracers or radiation (21,22) . These OCTA measures disclosed greater ONH-BFA values in patients with FMS, in contrast to those reported by several previous studies, as well as a weak correlation between ONH-BFA and increased disease severity.…”
Section: Discussionmentioning
confidence: 99%
“…The increase in RPC VD reflected a mild but true increase in microvascular blood flow around optic nerve head after SO removal. The repeatability of OCT angiography measurements had been well demonstrated in previous studies [19,20]. Factors that could influence the accuracy of OCT angiography measurements included IOP fluctuation [21], refractive media opacity and insufficient signal strength [20,22,23], diurnal variations and blood pressure changes [24].…”
Section: Discussionmentioning
confidence: 70%
“…Patients with glaucoma and healthy patients without glaucoma (control group) were recruited from the ophthalmology clinics at Tan Tock Seng Hospital, Singapore, between April 2015 and April 2016. This study is an expansion of patients recruited from our previous studies [ 13 , 16 ] which evaluated the microvascular density of optic nerve head and macula in healthy and glaucoma subjects using 1 OCTA device. This cross-sectional, prospective, observational study was approved by the Institutional Review Board of the National Healthcare Group and was conducted in accordance to the ethical standards stated in the Declaration of Helsinki.…”
Section: Methodsmentioning
confidence: 99%