Optical Assessment and Expected Visual Quality of Four Extended Range of Vision Intraocular Lenses

Abstract: PURPOSE: To assess the optical performance of four extended range of vision (ERV) intraocular lenses (IOLs) and predict the visual quality of the average pseudophakic patient. METHODS: Four ERV IOLs (LuxSmart, Bausch & Lomb; Vivity, Alcon Laboratories, Inc; Tecnis Eyhance, Johnson & Johnson Vision; and Isopure, PhysIOL) were inserted in an on-bench model eye. Their performance was assessed using through-focus modulation transfer function (MTF)–b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
16
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 27 publications
2
16
0
Order By: Relevance
“…The visual quality evaluated with the double-pass system OQAS showed similar MTF and SR values for both lenses, although the MTF cut-off frequency was higher than normal for both lenses, having an average value close to 30 c/deg, with the 4.0-mm pupil diameter set with the OQAS. These 'in-vivo' findings with the ISOPure lens are in line with those obtained by Alarcon et al 19 and Azor-Moron et al 20 on an optical bench.…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…The visual quality evaluated with the double-pass system OQAS showed similar MTF and SR values for both lenses, although the MTF cut-off frequency was higher than normal for both lenses, having an average value close to 30 c/deg, with the 4.0-mm pupil diameter set with the OQAS. These 'in-vivo' findings with the ISOPure lens are in line with those obtained by Alarcon et al 19 and Azor-Moron et al 20 on an optical bench.…”
Section: Discussionsupporting
confidence: 90%
“…These ‘in‐vivo’ findings with the ISOPure lens are in line with those obtained by Alarcon et al 19 . and Azor‐Moron et al 20 . on an optical bench.…”
Section: Discussionmentioning
confidence: 96%
“…After the full text evaluation, three clinical studies were excluded since the inclusion criteria was not accomplished, [11][12][13] and one mixed was maintained (partly excluded) since the criteria was accomplished in the laboratory study context but not in the clinical [14]. During the search update in the moment of data extraction, three papers were included, two not indexed in the databases and found through snowballing techniques, [15,16] and 1 new after search update [17]. Finally, 38 studies were included in the data extraction process (Fig.…”
Section: Study Inclusionmentioning
confidence: 99%
“…With regard optical quality metrics, the depth of focus achieved for predicted visual acuity of 0.2 logMAR and the increase range in comparison to a standard monofocal was retrieved for 4 manuscripts (Table 1) [15,[18][19][20]. Three papers showed the influence of the IOL centration on the modulation transfer function (MTF) at 50 lp/mm (Table 2) [21][22][23].…”
Section: Laboratory Studiesmentioning
confidence: 99%
“…19 We would anticipate that the slightly increased depth of focus that has been reported with this IOL depends on pupil constriction induced by accommodation. 20,21 Our visual tests were performed with a fixed pupil size of 4.5 mm. As such, the finding that the IOL with zero SA had better DCIVA at low contrast was anticipated.…”
Section: Discussionmentioning
confidence: 99%