2021
DOI: 10.1186/s42466-021-00133-0
|View full text |Cite
|
Sign up to set email alerts
|

Optic disc drusen mimicking Idiopathic Intracranial Hypertension (IIH): rely on ultrasound

Abstract: Optic nerve ultrasound is an established routine supplementary diagnostic tool for idiopathic intracranial pressure but it can also be helpful in avoiding misdiagnoses. We describe a case of an obese 15- year-old girl with persistent headaches, fundoscopic findings suggesting papilledema, normal brain imaging who underwent two lumbar punctures with unremarkable cerebrospinal fluid findings before ultrasound revealed optic disc drusen as the cause of the optic disc elevation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Optic nerve head drusen was responsible for 6% of misdiagnoses of IIH. B-scan ultrasound is considered diagnostic if there is an area of hyperreflectivity present at the nerve head or if acoustic shadowing of posterior structures of the optic nerve head is detected [ 33 ].…”
Section: Clinical Manifestations and Diagnosis Criteria Of Idiopathic...mentioning
confidence: 99%
“…Optic nerve head drusen was responsible for 6% of misdiagnoses of IIH. B-scan ultrasound is considered diagnostic if there is an area of hyperreflectivity present at the nerve head or if acoustic shadowing of posterior structures of the optic nerve head is detected [ 33 ].…”
Section: Clinical Manifestations and Diagnosis Criteria Of Idiopathic...mentioning
confidence: 99%
“…Although definitive differential diagnosis can be made using invasive method, LP, it is difficult to distinguish those two diseases with anamnesis and non-invasive techniques such as imaging modalities. [39][40][41][42] Despite studies showing a decrease in vessel density in cases of IIH and ODD compared with healthy controls, no study has compared those two groups. In our study, we therefore sough to evaluate the role of OCTA, which today's advancing technology offers, in the non-invasive differentiation of the two diseases.…”
Section: Discussionmentioning
confidence: 99%
“…TOS was performed by two trained neurologists (EB and GT), certified in neurosonology and with high expertise in TOS 9–12 . The operators were blinded to the clinical presentation and the final diagnosis of the patients.…”
Section: Methodsmentioning
confidence: 99%
“…TOS was performed by two trained neurologists (EB and GT), certified in neurosonology and with high expertise in TOS. [9][10][11][12] The operators were blinded to the clinical presentation and the final diagnosis of the patients. Philips CX50 Ultrasound System with a linear transducer at 9 MHz was used and TOS was performed prior to the lumbar puncture in all patients and before any therapeutic measures were initiated.…”
Section: Ultrasound Examinationmentioning
confidence: 99%