2013
DOI: 10.1016/j.fusengdes.2013.05.063
|View full text |Cite
|
Sign up to set email alerts
|

Operational status of the Magnum-PSI linear plasma device

Abstract: h i g h l i g h t s• High heat flux, high density plasmas in a highly accessible linear plasma device.• Plasma exposure of targets of different sizes under selectable plasma beam angles.• Dedicated plasma and surface diagnostics.• Differential vacuum pumping system. a r t i c l e i n f o b s t r a c tThe construction phase of the linear plasma generator Magnum-PSI at the FOM institute DIFFER has been completed and the facility has been officially opened in March 2012. The scientific program to gain more insig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 5 publications
0
18
0
Order By: Relevance
“…A K-Thermocouple is used to monitor the stage temperature. WO x coatings, deposited on W substrates and not annealed, were exposed to high-flux deuterium plasmas in the linear plasma generator Magnum-PSI at FOM-DIFFER [22,23] at low surface temperature (maximum temperature in center of plasma beam of T max = 580 K). The electron density and temperature of the plasma were measured with Thomson scattering [24].…”
Section: Methodsmentioning
confidence: 99%
“…A K-Thermocouple is used to monitor the stage temperature. WO x coatings, deposited on W substrates and not annealed, were exposed to high-flux deuterium plasmas in the linear plasma generator Magnum-PSI at FOM-DIFFER [22,23] at low surface temperature (maximum temperature in center of plasma beam of T max = 580 K). The electron density and temperature of the plasma were measured with Thomson scattering [24].…”
Section: Methodsmentioning
confidence: 99%
“…The increase in ∆T is illustrated in figure 9 where 50 laser pulses at F HF = 25.2 MJ m −2 s −1/2 are applied in combination with steady-state plasma exposure. The slight decrease in base temperature through the discharge is due to a diminishing magnetic field strength leading to a decrease in power input to the plasma [13,25]. This should have no effect on the transient temperature rise induced by the laser.…”
Section: Power Handlingmentioning
confidence: 99%
“…This study aims to bridge such a gap by performing experiments using the Magnum-PSI device [11] relevant to inter-ELM radiative divertor conditions in ITER. The results clearly demonstrate that surface impurities (N or Mo) increases D retention in W due to enhanced trapping at the near surface as well as increased retention in the bulk.…”
Section: Introductionmentioning
confidence: 99%