2001
DOI: 10.1016/s1369-703x(01)00100-0
| |Summarize |Cite
|
Sign up to set email alerts

Operating parameters for a gas–liquid–solid fluidised bed bioreactor with a low density biomass support

Search citation statements

Order By: Relevance

Paper Sections

Select...
23
1
1
0

Citation Types

0
11
0
0

Year Published

Range
2003
2003
2027
2027

Publication Types

Select...
20
2
1

Relationship

2
21

Authors

Journals

Cited by 23 publications

(11 citation statements)

References 20 publications

0
11
0
0
Order By: Relevance
How the paper below cites the one you are viewing
“…It can be noted in Figs 4–6 that the largest reduction in COD was attained at ( V b / V R ) m = 0.55. An increase in COD removal with an increase in the ( V b / V R ) from 0.50 to 0.55 can be attributed to the fact that for increasing ( V b / V R ), more biomass grown on the particles participated in degradation of the constituents of the wastewater 5, 12. On the other hand, a decrease in COD removal observed with an increase in ( V b / V R ) from 0.55 to 0.60 was due to the fact that, in this case, a significant volume of the bioreactor was occupied by the support media and consequently the aeration characteristics of the bed has worsened 5, 7…”
Section: Results
mentioning
confidence: 99%
“…As can be noted, for example in Fig 4, reduction in COD initially increased monotonically, and then decreased with an increase in u , attaining the largest value at u = 0.031 m s −1 . This can be explained by the fact that with an increase in u up to 0.031 m s −1 , the aeration conditions for oxygen transfer improved and consequently the amount of the oxygen supplied for biomass growth increased 5, 7. Since, according to Lee and Buckley,16 bubble size varies little with air velocity and hence an interfacial (air–liquid) area is mainly determined by the air velocity, thus with an increase in u the interfacial area increased, which was desirable for air–liquid oxygen transfer.…”
Section: Results
mentioning
confidence: 99%
“…It can be noticed in Fig 4 that an increase in u above 0.031 m s −1 had no effect on reduction in COD values. Thus, for the air velocities greater than 0.031 m s −1 , the degradation rate of the constituents of the wastewaters was the controlling factor of the treatment process 5, 16–18…”
Section: Results
mentioning
confidence: 99%
“…A schematic illustration of a TPFBB for wastewater treatment is shown in Fig 1. In a bioreactor with low density particles, fluidisation can be conducted either by an upward cocurrent flow of gas and liquid through a bed (Fig 1)5, 7 or by a downward flow of liquid and countercurrent upward flow of gas 10, 11. In both cases, an inverse fluidisation occurs, that is, the fluidised bed expands downwards.…”
Section: A Tpfbb With Low Density Particles
mentioning
confidence: 99%
See 3 more Smart Citations