13th IET International Conference on AC and DC Power Transmission (ACDC 2017) 2017
DOI: 10.1049/cp.2017.0054
|View full text |Cite
|
Sign up to set email alerts
|

Open access simulation toolbox for the grid connection of offshore wind farms using multi-terminal HVDC networks

Abstract: This version is available at https://strathprints.strath.ac.uk/61139/ Strathprints is designed to allow users to access the research output of the University of Strathclyde. Unless otherwise explicitly stated on the manuscript, Copyright © and Moral Rights for the papers on this site are retained by the individual authors and/or other copyright owners. Please check the manuscript for details of any other licences that may have been applied. You may not engage in further distribution of the material for any pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 4 publications
0
12
0
Order By: Relevance
“…In the present case, 5 sections have been considered in order to account for the hyperbolic correction factors, which improve the detail of the model specially for long cables. Furthermore, a wideband frequency-dependent cable model from the Best Paths project open source library [25] has been used in the time-domain simulations in order to show that the model is accurate.…”
Section: Fig 2 Electrical Model Of the MMC Connected To A Grid Thévmentioning
confidence: 99%
See 1 more Smart Citation
“…In the present case, 5 sections have been considered in order to account for the hyperbolic correction factors, which improve the detail of the model specially for long cables. Furthermore, a wideband frequency-dependent cable model from the Best Paths project open source library [25] has been used in the time-domain simulations in order to show that the model is accurate.…”
Section: Fig 2 Electrical Model Of the MMC Connected To A Grid Thévmentioning
confidence: 99%
“…The small-signal analysis will be performed under this assumption for the AC power loop, and the performance will be verified through the non-linear time-domain simulation model. For the frequency-domain analysis, the following transfer functions are of interest: The specifications are defined imposing a limit in the maximum singular values (25) of such transfer functions:…”
Section: Evaluation Of the Control Performance And Analysis Of Comentioning
confidence: 99%
“…Selecting a suitable cable model is a crucial aspect in electromagnetic transient simulations. In this paper, we use the Universal Line Model (also known as wideband model) from the BestPaths open access Simulink toolbox [20] that captures the frequency dependent behaviour of the cable.…”
Section: Cable Modelmentioning
confidence: 99%
“…1 … represent the CLRs' inductances. 1 … and 1 … are the inductances and capacitances of the nearby connected dc network. The resistance of the bypass branches is negligible as it is much smaller than the equivalent resistance (RMB1 for BT-ICBtyp1 and RMB2 for BT-ICBtyp2) and the forward voltage drop of semiconductors of the BTMB ( 1 for BT-ICBtyp1 and 2 for BT-ICBtyp2).…”
Section: Analysis and Design Of Bt-icbs A Parametric Analysis Omentioning