2013
DOI: 10.1016/j.acra.2013.07.008
|View full text |Cite
|
Sign up to set email alerts
|

Online Training on the Safe Use of Fluoroscopy Can Result in a Significant Decrease in Patient Dose

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(22 citation statements)
references
References 12 publications
0
22
0
Order By: Relevance
“…P KA for specific interventional procedures is not normally distributed and often approximates a lognormal distribution . Variations in P KA are due to differences in patient body habitus, fluoroscopy technology, operator skill and training, and the complexity of individual cases of a given procedure …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…P KA for specific interventional procedures is not normally distributed and often approximates a lognormal distribution . Variations in P KA are due to differences in patient body habitus, fluoroscopy technology, operator skill and training, and the complexity of individual cases of a given procedure …”
Section: Discussionmentioning
confidence: 99%
“…75,76 Variations in P KA are due to differences in patient body habitus, fluoroscopy technology, operator skill and training, and the complexity of individual cases of a given procedure. 28,33,[77][78][79][80][81] When considering the relationship between P KA values and associated estimates of E, it is important to remember that P KA is defined to exclude backscatter. An unknown and variable amount of backscatter contributes to absorbed dose, and thus to the uncertainty of E. It is also essential to realize that the international safety standard for fluoroscopy equipment specifies that an overall uncertainty of up to 35% in displayed values of P KA is acceptable.…”
Section: A Uncertaintiesmentioning
confidence: 99%
“…In our experience, a kinesthetic format is not needed on an annual basis for individuals who have already had kinesthetic education or for which routine practices have incorporated the applicable safe practices. 12,13 Class room presentations are given annually by a QMP build on the kinesthetic training and thus generally follow similar content. See attached slide presentation content ( Figs.…”
Section: Discussionmentioning
confidence: 99%
“…All efforts to reduce pediatric radiation exposure should be made. Effective fluoroscopic safety training can result in a significant decrease in patient dose; this is coupled with the added benefit of reduced operator exposure [18]. …”
Section: Discussionmentioning
confidence: 99%