2022
DOI: 10.1016/j.egyr.2022.05.140
|View full text |Cite
|
Sign up to set email alerts
|

Online management and assessment of power quality issues through smart metering in smart grid architecture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…The paper [14] provides an overview of PQ analysis, compensators, and control technologies under the new SG situation. The importance of AMI in SG architecture for online management and assessment of PQ issues was recently elaborated in [15]. The findings of the large-scale and long-lasting PQ monitoring project in Australia are reported in [16].…”
Section: Literature Reviewmentioning
confidence: 99%
“…The paper [14] provides an overview of PQ analysis, compensators, and control technologies under the new SG situation. The importance of AMI in SG architecture for online management and assessment of PQ issues was recently elaborated in [15]. The findings of the large-scale and long-lasting PQ monitoring project in Australia are reported in [16].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Temporal align layer is a collection of single perceptron layers noted as [ f k ] K k=0 : R Z  → R K×d , where the single perceptron layer is a mapping function f k : R zk  → R d . Subsequently, the temporal aligned MSD output, M is obtained as follows, (6) where M ∈ R K×d and fixed embedding output d = 256 is used.…”
Section: Temporal Align Layermentioning
confidence: 99%
“…These power quality issues may lead to reliability of power delivery, devices malfunctioning, and reduced lifespan of electric components [4]. Hence, power quality monitoring is of paramount importance with addition to future development of smart grids [5,6]. Classification of power quality disturbance is the main feature required in a power monitoring systems.…”
Section: Introductionmentioning
confidence: 99%
“…The paper [14] provides an overview of PQ analysis, compensators, and control technologies under the new situation of SG. The importance of AMI in SG architecture for online management and assessment of PQ issues is recently elaborated in [15]. The findings of the large scale and long lasting PQ monitoring project in Australia are reported in [16].…”
Section: Literature Reviewmentioning