1987
DOI: 10.1007/bf02881248
|View full text |Cite
|
Sign up to set email alerts
|

One-electron reduction of thionine studied by pulse radiolysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
80
0

Year Published

1998
1998
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 304 publications
(85 citation statements)
references
References 13 publications
5
80
0
Order By: Relevance
“…Electron donors 2,2′-azino-bis­(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and N , N , N ′, N ′-tetramethyl- p -phenylenediamine (TMPD) were obtained from Sigma-Aldrich. The nanosecond pulse radiolysis system employing 7 MeV electrons has been described elsewhere . For a 200 ns pulse, the measured dose was 37 Gy, and for a 500 ns pulse, the measured dose was 42 Gy.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Electron donors 2,2′-azino-bis­(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and N , N , N ′, N ′-tetramethyl- p -phenylenediamine (TMPD) were obtained from Sigma-Aldrich. The nanosecond pulse radiolysis system employing 7 MeV electrons has been described elsewhere . For a 200 ns pulse, the measured dose was 37 Gy, and for a 500 ns pulse, the measured dose was 42 Gy.…”
Section: Methodsmentioning
confidence: 99%
“…The nanosecond pulse radiolysis system employing 7 MeV electrons has been described elsewhere. 25 For a 200 ns pulse, the measured dose was 37 Gy, and for a 500 ns pulse, the measured dose was 42 Gy. The dosimetry was carried out using an air-saturated aqueous solution containing 5 × 10 −2 M KSCN (Gε = 2.59 ± 0.05 m 2 J −1 at 475 nm).…”
Section: ■ Introductionmentioning
confidence: 97%
“…Electron pulse radiolysis experiments were performed using a set-up which has already been discussed in detail elsewhere. 30 TA profiles and time-resolved TA spectra were recorded with subpicosecond time resolution (B120 fs) using a pump-probe spectrometer, which has been described in detail elsewhere. 31 Briefly, it uses a amplified laser system based on a Ti : sapphire oscillator (Thales Optronique SA, Elancourt, France).…”
Section: Methodsmentioning
confidence: 99%
“…Pulse radiolysis experiments with optical detection were carried out using 7 MeV electron pulses (pulse width 50 ns) from a linear accelerator at the Bhabha Atomic Research Centre, Mumbai as described previously. 18 A KSCN dosimeter was used in the optical pulse radiolysis. The dose per pulse was between 10-15 Gy.…”
Section: Methodsmentioning
confidence: 99%