2017
DOI: 10.1007/978-3-319-61813-5_1
|View full text |Cite
|
Sign up to set email alerts
|

On the Impact of Using Public Network Communication Infrastructure for Voltage Control Coordination in Smart Grid Scenario

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 6 publications
0
12
0
Order By: Relevance
“…Since the work presented in [1,[6][7][8]16] is mainly based on offline or non-Real-Time (non-RT) co-simulation framework, the authors in this paper prove through real-time set of recordings that the control concepts developed in [1,6,16] are valid. The validation is done by first verifying and validating the proposed ICT model for non-RT studies in [7,8] through different test cases against the complete network model and related data traffic implemented in the SES Lab. Based on the results, the validation of coordinated voltage control for ReGen plants in Medium Voltage (MV) grids is achieved.…”
Section: Introductionmentioning
confidence: 93%
See 4 more Smart Citations
“…Since the work presented in [1,[6][7][8]16] is mainly based on offline or non-Real-Time (non-RT) co-simulation framework, the authors in this paper prove through real-time set of recordings that the control concepts developed in [1,6,16] are valid. The validation is done by first verifying and validating the proposed ICT model for non-RT studies in [7,8] through different test cases against the complete network model and related data traffic implemented in the SES Lab. Based on the results, the validation of coordinated voltage control for ReGen plants in Medium Voltage (MV) grids is achieved.…”
Section: Introductionmentioning
confidence: 93%
“…The violation of this limit at certain points within the grid may possibly lead to severe stability problems and damage to the entire power system [6]. Although each ReGen plant can contribute to voltage regulation, as ascertained in [7,16], there can be additional control objectives required by the DSO, for example to reduce the grid power losses caused by reactive power provision. This objective can be accomplished by optimizing the control settings in the distributed online coordination scheme, as defined in [16], which constitutes an NCS of the SG developed on top of a communication network.…”
Section: Distributed Online Voltage Coordination Concept and Rt-hil Fmentioning
confidence: 99%
See 3 more Smart Citations