2014
DOI: 10.1007/s00340-014-5925-8
|View full text |Cite
|
Sign up to set email alerts
|

On-line wavelength calibration of pulsed laser for CO2 DIAL sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…Therefore, we focus on frequency drift of the on-line wavelength herein. The frequency drift induced error reaches its peak at the wings of a CO2 spectrum, while it falls to a much lower value at the absorption peak according to previous studies [39,59,60]. Consequently the on-line wavenumber could move to the absorption peak of the CO2 spectrum and the error would decrease by one order of magnitude, as also shown in Figure 9.…”
Section: Estimation Of the Systematic Errormentioning
confidence: 60%
“…Therefore, we focus on frequency drift of the on-line wavelength herein. The frequency drift induced error reaches its peak at the wings of a CO2 spectrum, while it falls to a much lower value at the absorption peak according to previous studies [39,59,60]. Consequently the on-line wavenumber could move to the absorption peak of the CO2 spectrum and the error would decrease by one order of magnitude, as also shown in Figure 9.…”
Section: Estimation Of the Systematic Errormentioning
confidence: 60%
“…The laser of the target wavelength is generated via difference frequency mixing between the fundamentals of the Nd:YAG laser (1064 nm) and the dye laser (634 nm), which is pumped by the second harmonic of the Nd:YAG (532 nm). As a consequence, the wavelength of the output laser can be changed by tuning the dye laser whose wavelength is changed by a stepper motor [30]. In the DIAL system, the high-precision frequency calibration of the on-line wavelength has a significant influence on inversion precision.…”
Section: Methodsmentioning
confidence: 99%
“…One of the broadening mechanisms produces a Gaussian profile as a result of the Doppler broadening; the other produces a Lorentz profile. Because of its physical implications, the Voigt function is superior to other functions for obtaining the absorption line of CO 2 [25]. The H 2 O curve, which marks the right axis, is on a log scale, given that the intensities of the lines are much smaller than those of CO 2 .…”
Section: Simulation Analysismentioning
confidence: 99%
“…In the laboratory experiments of DW-DIAL, the absorption spectra of CO 2 was first obtained using a gas cell with a large scale of approximately 10 pm, and the absorption spectra of CO 2 at the region of R16 was located using a wavemeter whose accuracy was approximately 5 pm. After locating R16, we conducted a fine scanning at a step size of 3 pm and obtained the location of the on-line wavelength using a wavelength stabilization program, about which a detailed introduction is in [25]. The laser of the on-line wavelength was then imported into the gas absorption cell of the 16-m range, and the OD was obtained using the oscilloscope, following the collection procedures.…”
Section: Experiments With Laboratory Signalmentioning
confidence: 99%
See 1 more Smart Citation