CO 2 is one of the most important greenhouse gases. Its concentration and distribution in the atmosphere have always been important in studying the carbon cycle and the greenhouse effect. This study is the first to validate the XCO 2 of satellite observations with total carbon column observing network (TCCON) data and to compare the global XCO 2 distribution for the passive satellites Orbiting Carbon Observatory-2 (OCO-2) and Greenhouse Gases Observing Satellite (GOSAT), which are on-orbit greenhouse gas satellites. Results show that since GOSAT was launched in 2009, its mean measurement accuracy was −0.4107 ppm with an error standard deviation of 2.216 ppm since 2009, and has since decreased to −0.62 ppm with an error standard deviation of 2.3 ppm during the past two more years (2014)(2015)(2016), while the mean measurement accuracy of the OCO-2 was 0.2671 ppm with an error standard deviation of 1.56 ppm from September 2014 to December 2016. GOSAT observations have recently decreased and lagged behind OCO-2 on the ability to monitor the global distribution and monthly detection of XCO 2 . Furthermore, the XCO 2 values gathered by OCO-2 are higher by an average of 1.765 ppm than those by GOSAT. Comparison of the latitude gradient characteristics, seasonal fluctuation amplitude, and annual growth trend of the monthly mean XCO 2 distribution also showed differences in values but similar line shapes between OCO-2 and GOSAT. When compared with the NOAA statistics, both satellites' measurements reflect the growth trend of the global XCO 2 at a low and smooth level, and reflect the seasonal fluctuation with an absolutely different line shape.
High-accuracy on-line wavelength stabilization is required for differential absorption lidar (DIAL), which is ideal for precisely measuring atmospheric CO(2) concentration. Using a difference-frequency laser, we developed a ground-based 1.57-μm pulsed DIAL for performing atmospheric CO(2) measurements. Owing to the system complexity, lacking phase, and intensity instability, the stabilization method was divided into two parts-wavelength calibration and locking-based on saturated absorption. After obtaining the on-line laser position, accuracy verification using statistical theory and locking stabilization using a one-dimensional template matching method, namely least-squares matching (LSM), were adopted to achieve wavelength locking. The resulting system is capable of generating a stable wavelength.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.