2007
DOI: 10.1118/1.2777006
|View full text |Cite
|
Sign up to set email alerts
|

On‐line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom

Abstract: For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is proposed using a 2D ion chamber array (Seven29, PTW, Freiburg, Germany) inserted in a dedicated octagonal phantom, called O… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
107
0
2

Year Published

2011
2011
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 120 publications
(111 citation statements)
references
References 52 publications
2
107
0
2
Order By: Relevance
“…From the perspective of efficient and reliable quality assurance (QA), 2D arrays with ionization chambers or diodes have been widely used and characterized for dose verification of IMRT 11 , 19 and VMAT 20 , 29 . One such device is the 2D ionization chamber array I'mRT MatriXX (IBA Dosimetry, Bartlett, TN).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…From the perspective of efficient and reliable quality assurance (QA), 2D arrays with ionization chambers or diodes have been widely used and characterized for dose verification of IMRT 11 , 19 and VMAT 20 , 29 . One such device is the 2D ionization chamber array I'mRT MatriXX (IBA Dosimetry, Bartlett, TN).…”
Section: Introductionmentioning
confidence: 99%
“…Van Esch et al (20) considered the angular dependence of a 2D ionization chamber array (Seven29, PTW‐Freiburg, Germany) by using a dedicated octagonal phantom (OCTAVIUS, PTW). Jursinic et al (24) modified a 2D diode array (MapCHECK, Sun Nuclear, Melbourne, FL) by considering the angular dependence.…”
Section: Introductionmentioning
confidence: 99%
“…Also, the decreasing supply of film and photographic chemicals makes it necessary to find other alternatives. ( 5 , 6 ) …”
Section: Discussionmentioning
confidence: 99%
“…( 4 ) Recently, several authors have pointed out the current trend to move to digital imaging. This trend has resulted in a decline in the availability of films and chemical processors, ( 5 , 6 ) which led us to look for alternative methods for this type of control.…”
Section: Introductionmentioning
confidence: 99%
“…Electronic portal imaging devices (EPIDs) have also been tested for in vivo dosimetry purposes (12) . In phantom, verification of the treatment plan in three dimensions (3D) can be carried out successfully using Delta 4 (Scandidos AB, Uppsala, Sweden), (23) ArcCHECK (Sun Nuclear Corp.), 5 , 24 , 25 , 26 and Octavius (PTW, Freiburg, Germany) (27) …”
Section: Introductionmentioning
confidence: 99%