A method to enhance spatial resolution of a 2D ion chamber array for quality control of MLC

Abstract: This work introduces a new method for verifying MLC leaf positions with enough spatial resolution to replace film‐based methods in performing QA tests. It is implemented on a 2D ion chamber array, and it is based on the principle of varying signal response of a volumetric detector to partial irradiation. A PTW 2D‐ARRAY seven29 (PTW‐729 2D) array was used to assess a Siemens OPTIFOCUS MLC. Partial volume response curves for chambers in the array were obtained by irradiating them with the leaves of the MLC, prog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
6
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…2,12,15,27,29 EPIDs have been used for the QA of MLC performance in several studies. 7,9,15,[25][26][27][30][31][32][33] There have also been reports on the application of 2D array detectors such as MapCheck, MatriXX, and PTW-729 34,35 for this purpose. The major concern about these devices is their low spatial resolution.…”
Section: Introductionmentioning
confidence: 99%
“…2,12,15,27,29 EPIDs have been used for the QA of MLC performance in several studies. 7,9,15,[25][26][27][30][31][32][33] There have also been reports on the application of 2D array detectors such as MapCheck, MatriXX, and PTW-729 34,35 for this purpose. The major concern about these devices is their low spatial resolution.…”
Section: Introductionmentioning
confidence: 99%
“…This type of error would occur if a single leaf requires recalibration and, even for these small magnitudes, could become significant for small field stereotactic treatments. Single‐leaf miscalibration errors on a small scale may not be detected by other QA methods, such as those which rely on DynaLog files (14) or low‐resolution devices 25 , 26 …”
Section: Discussionmentioning
confidence: 99%
“…Single-leaf miscalibration errors on a small scale may not be detected by other QA methods, such as those which rely on DynaLog files (14) or low-resolution devices. (25,26) Random leaf calibration errors may occur when a MLC has not been initialized frequently enough. These types of errors can easily be visualized in Figs.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, film requires careful handling, processing, and can become expensive over time. Alternatively, some researchers have proposed methods for increasing the spatial resolution of 2D detector arrays (Poppe et al 2007, Diaz Moreno et al 2011. Poppe et al (2007) successfully doubled the spatial resolution of a 2D detector array by performing two measurements; the first measurement with a standard detector array position and the second performed with a position offset of half the detector spacing.…”
Section: Introductionmentioning
confidence: 99%