2004
DOI: 10.1016/j.aca.2004.03.058
|View full text |Cite
|
Sign up to set email alerts
|

On-line preconcentration capillary electrophoresis for purity profiling of synthetic peptides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…A method was optimized and evaluated for the purity control of the biologically active synthetic peptide fas-F (a 28-residue fragment of fasciculin-1) and applied to purity profiling of angiotensin I, oxytocin, bradykinin, and luteinizing-hormonereleasing hormone with an in-line concentrator cartridge, packed with silica-based C-18 particles and coupled near the inlet of the capillary [19]. Fig.…”
Section: C-18mentioning
confidence: 99%
“…A method was optimized and evaluated for the purity control of the biologically active synthetic peptide fas-F (a 28-residue fragment of fasciculin-1) and applied to purity profiling of angiotensin I, oxytocin, bradykinin, and luteinizing-hormonereleasing hormone with an in-line concentrator cartridge, packed with silica-based C-18 particles and coupled near the inlet of the capillary [19]. Fig.…”
Section: C-18mentioning
confidence: 99%
“…Schematic representation of the analyte concentrator cartridge. Reprinted from [100] with permission from Elsevier. many cases, however, the increase in signal output is largely limited by the volume of the capillary itself, since a good length must remain for separation of the sample components.…”
Section: Chromatographic Preconcentrationmentioning
confidence: 97%
“…Instead of nanoliter volumes typically used in CE, at least 25 L of the sample could be loaded, resulting in three to four orders of magnitude improvement in detections limits. Vizioli et al [100] packed a short length of fused silica capillary with silica-based C 18 reversed-phase chromatographic material, and coupled it on-line with the separation capillary (Fig. 4).…”
Section: Chromatographic Preconcentrationmentioning
confidence: 99%
See 1 more Smart Citation
“…In particular, quantitative detection of oxytocin levels in human saliva would be an indicator to monitor the relationship between psychological changes and peripheral effects. 8 Oxytocin has been conventionally analyzed utilizing large analytical apparatuses (e.g., liquid chromatography-mass spectrometry (LC-MS) [9][10][11] and capillary electrophoresis, 12,13 while such methods have considerable issues such as the requirement of expensive large instruments and trained personnel, and time-consuming. In the context of the above, the development of a rapid and facile sensing system is desirable.…”
mentioning
confidence: 99%