2000
DOI: 10.1016/s0021-9673(00)00259-4
|View full text |Cite
|
Sign up to set email alerts
|

On-line isotachophoretic sample focusing for loadability enhancement in capillary electrochromatography–mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2000
2000
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 34 publications
0
16
0
Order By: Relevance
“…Besides this, the on-line isotachophoretic stage can serve also for a loadability enhancement (due to a large inner diameter of the ITP capillary). Both of these effects are then responsible for a dramatic reduction of the sample concentration detection limits through simultaneous acting of (i) large volume injection and (ii) analyte stacking (Mazereeuw et al, 2000). In the ITP-CEC combination (Fig.…”
Section: Itp-cecmentioning
confidence: 99%
See 1 more Smart Citation
“…Besides this, the on-line isotachophoretic stage can serve also for a loadability enhancement (due to a large inner diameter of the ITP capillary). Both of these effects are then responsible for a dramatic reduction of the sample concentration detection limits through simultaneous acting of (i) large volume injection and (ii) analyte stacking (Mazereeuw et al, 2000). In the ITP-CEC combination (Fig.…”
Section: Itp-cecmentioning
confidence: 99%
“…The ITP-CEC-MS hyphenation seems to be one of the most promissing methods for the fully automatized biomedical chiral analyses such as enantioselective pharmacokinetic studies, metabolomics, etc. (Mazereeuw et al, 2000). (1 and 2) and 75 m (3) are used.…”
Section: Itp-cecmentioning
confidence: 99%
“…Mazereeuw et al [35] have used on-line isotachophoretic sample focusing for loadability enhancement in CEC-MS. A coupled-column setup was used with a 220 mm ID capillary, in which counterflow focusing was performed, connected via a T-junction to a 75 mm ID CEC capillary. The use of isotachophoretic focusing resulted in a dramatic reduction of the analyte LODs.…”
Section: Clenbuterol and Salbutamolmentioning
confidence: 99%
“…Such coupling allows flexible and precise manipulation of both extraction and separation processes. Tjaden and co-workers [22] reported the on-line preconcentration of charged solutes via isotachophoretic sampling focusing in untreated fused-silica capillaries prior to CEC separation and UV/MS detection. Jinno and co-workers [23] established the on-line coupling of fiber-in-tube solid-phase microextraction (SPME) with CEC and reported its successful application to the preconcentration and separation of phthalate mixtures in water samples.…”
Section: Introductionmentioning
confidence: 99%