2002
DOI: 10.1007/s00216-002-1677-0
|View full text |Cite
|
Sign up to set email alerts
|

On-line complexation/cloud point preconcentration for the sensitive determination of dysprosium in urine by flow injection inductively coupled plasma–optical emission spectrometry

Abstract: An on-line dysprosium preconcentration and determination system based on the hyphenation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with ICP-OES was studied. For the preconcentration of dysprosium, a Dy(III)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex was formed on-line at pH 9.22 in the presence of nonionic micelles of PONPE-7.5. The micellar system containing the complex was thermostated at 30 degrees C in order to promote phase separation, and the surfactant-rich p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
21
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 46 publications
(25 citation statements)
references
References 22 publications
1
21
0
Order By: Relevance
“…In procedures using CPE, Br-PADAP has been used for determination of vanadium [18] mercuric [20], dysprosium [36], and gadolinium [37]. This paper proposes a preconcentration procedure for determination of nickel in saline aqueous waste samples by FAAS.…”
Section: Introductionmentioning
confidence: 99%
“…In procedures using CPE, Br-PADAP has been used for determination of vanadium [18] mercuric [20], dysprosium [36], and gadolinium [37]. This paper proposes a preconcentration procedure for determination of nickel in saline aqueous waste samples by FAAS.…”
Section: Introductionmentioning
confidence: 99%
“…30 It has been shown to be an effective sample preconcentration technique for improving the sensitivity and selectivity prior to flame AAS, HPLC, capillary electrophoresis and flow injection analysis. [31][32][33][34] Application of surfactant not only facilitates sensitivity enhancement but also avoids the use of toxic solvents in absorbance measurements. This aspect means that it is in agreement with ''Green Chemistry'' principles.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, compared to the results obtained by other authors [6][7][8][9][10][11][12][13], the present on-line CPE/FIA system had many advantages, such as high sensitivity, high sample throughput, high extraction efficiency and simplicity. Experimental factors which govern the magnitude of the preconcentration factors and the CL intensity were studied.…”
Section: Introductionmentioning
confidence: 83%
“…When compared to all the reported on-line CPE/FIA papers [6][7][8][9][10][11][12][13], the key difference/improvement of the present on-line CPE/FIA system was that the collection column served a dual function: (1) to entrap the analyte-containing surfactant aggregates and (2) to provide CL emission (i.e., the collection column was mounted directly adjacent to the detector). Table 1 shows the effects on the CL intensity as a function of the presence (or absence) of the analyte (bilirubin), surfactant (Triton X-114), salting-out agent (Na 2 SO 4 ) and/or filtering material (cotton).…”
Section: Collection Columnmentioning
confidence: 99%
See 1 more Smart Citation