On Harmonic State Estimation of Power System With Uncertain Network Parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
24
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 51 publications
(24 citation statements)
references
References 36 publications
0
24
0
Order By: Relevance
“…Nonlinear electric appliances, which rely on power electronic switches, are widely used in the domestic and industrial utilization of every utility throughout the world [1,2]. The presence of nonlinear loads, such as personal computers, variable frequency drives (VFDs) and arc furnaces, gives rise to power quality problems, e.g., harmonic distortion, voltage fluctuation and noise [3][4][5]. Harmonic distortion in low-voltage distribution systems is responsible for power losses, electric devices heating, insulation failures, interference issues in communication systems and in the worst cases, electric power system failure [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…Nonlinear electric appliances, which rely on power electronic switches, are widely used in the domestic and industrial utilization of every utility throughout the world [1,2]. The presence of nonlinear loads, such as personal computers, variable frequency drives (VFDs) and arc furnaces, gives rise to power quality problems, e.g., harmonic distortion, voltage fluctuation and noise [3][4][5]. Harmonic distortion in low-voltage distribution systems is responsible for power losses, electric devices heating, insulation failures, interference issues in communication systems and in the worst cases, electric power system failure [6,7].…”
Section: Introductionmentioning
confidence: 99%
“…In this context, several papers presented in the literature have been focused on the evaluation of the harmonic pollution through the grid, applying Harmonic State Estimation methodologies (see for example [7]- [9]). These techniques, mostly derived from classic State Estimation methods originally designed for transmission systems, require a significant quantity of information, such as measured data, network topology and network parameters, to obtain an accurate evaluation of the quantities of interest.…”
Section: Introductionmentioning
confidence: 99%
“…Nowadays, with the utilization and popularization of renewable energy, including wind power, solar photovoltaic power, and electric vehicles, new harmonic sources have emerged in modern grids. Therefore, a great many harmonics are generated and injected into the power grid, deteriorating the power quality and bringing great harm to the equipment and grid [1,2]. Therefore, he harmonic elimination has been of extensive concern and investigated.…”
Section: Introductionmentioning