International Symposium on Air Quality and Manure Management for Agriculture Conference Proceedings, 13-16 September 2010, Dall 2010
DOI: 10.13031/2013.32639
|View full text |Cite
|
Sign up to set email alerts
|

Odor and Odorous Chemical Emissions from Animal Buildings: Part 2- Odor Emissions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Year Published

2010
2010
2013
2013

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…The analysis showed that both the h and k values suggested the IN5B barn 1 (ISU analysis) sample evaluation be investigated for sampling or assessment inconsistencies. This may indicate an outlying point or that panelists at ISU responded to barn odors from the IN5B site in an abnormal manner (a concept potentially supported by the lab × sample location interaction reported by Akdeniz, 2010). However, the collection and analysis documentation related to this sample did not indicate obvious discontinuity from other samples and analyses, and hence the data point was retained.…”
Section: Interlaboratory Olfactometry Comparisonmentioning
confidence: 96%
See 2 more Smart Citations
“…The analysis showed that both the h and k values suggested the IN5B barn 1 (ISU analysis) sample evaluation be investigated for sampling or assessment inconsistencies. This may indicate an outlying point or that panelists at ISU responded to barn odors from the IN5B site in an abnormal manner (a concept potentially supported by the lab × sample location interaction reported by Akdeniz, 2010). However, the collection and analysis documentation related to this sample did not indicate obvious discontinuity from other samples and analyses, and hence the data point was retained.…”
Section: Interlaboratory Olfactometry Comparisonmentioning
confidence: 96%
“…Both inter-and intralaboratory comparisons were made using standard comparative methods (ASTM, 2009). Additional olfactometry results for the normal sampling schedule can be found in the second article in this series (Akdeniz et al, 2012a).…”
Section: Interlaboratory Olfactometry Comparisonmentioning
confidence: 99%
See 1 more Smart Citation
“…OAV has also been called odor value, odor unit, flavor unit, and aroma value in various publications, although the definition is the same for each term. To avoid confusion, note that this is not the same "odor unit" used by Akdeniz et al (2012a) in part 2 of this series to quantify odor concentration using dynamic triangular forced-choice olfactometry.…”
Section: Odor Activity Valuementioning
confidence: 99%
“…In part 1, the overall project overview and collection methods are presented (Bereznicki et al, 2012). Part 2 focuses on odor emissions as measured using dynamic triangular forced-choice olfactometry with human panelists (Akdeniz et al, 2012a). In part 3, we present emission rates for chemical compounds (volatile organic compounds, VOC) as measured by GC/MS .…”
mentioning
confidence: 99%