Ocular Chances Associated with Continuous Wear of Contact Lenses

Abstract: This paper is based on clinkai data derived from 35 patients having worn a variety of contact lenses on a continuous wear basis for periods up to two years. Aspects discussed include oedema-induced changes in the ocular parameters, miscellaneous disturbances to corneal integrity end adverse eye reactlonr.Although there has been considerable variation in the corneel swelling response (depending on contact lens gas tranmlssbn, patient age and state of the comes), most patients have shown adaptation within the fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

1983
1983
2009
2009

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 1 publication
0
14
0
Order By: Relevance
“…According to the authors, corneal sensitivity and endothelial polymegathism could be used as indicators of long-term corneal hypoxia. Zantos et al 23 stated that large (15-50 m) epithelial microcysts sometimes emerge as a late response to hypoxia in contact lens wearers.…”
Section: Discussionmentioning
confidence: 98%
“…According to the authors, corneal sensitivity and endothelial polymegathism could be used as indicators of long-term corneal hypoxia. Zantos et al 23 stated that large (15-50 m) epithelial microcysts sometimes emerge as a late response to hypoxia in contact lens wearers.…”
Section: Discussionmentioning
confidence: 98%
“…The severity of microcysts has been reported to be associated with the duration of wearing low-Dk SCL and with continuous wearing of lenses. 1,2 In the present case, however, daily wear lenses were used for an average of about 12 hr per day. There have been no previous reports about the occurrence of so many microcysts in a person using high-Dk silicone hydrogel lenses on a daily basis.…”
Section: Eye and Contact Lens • Volume 35 Number 3 May 2009mentioning
confidence: 96%
“…Especially, toxic or severe sensitivity reaction to the solution and the solution/silicone-hydrogel lens interaction could be considered, and these possibilities were supported by previous study reported by Jones et al 10 Furthermore, we must consider about the other causes, for example, disorganized cellular growth, necrotic tissue, pockets of cellular debris, apoptosis, and so forth. 1,[11][12][13] With regard to lens care in the present case, it is noteworthy that no lens care solution is recommended by the manufacturer for Acuvue Oasys, so each lens wearers must individually check the compatibility of their lens care solution. In the present case, Medalist Plus had been used previously and should have caused no problems.…”
Section: Eye and Contact Lens • Volume 35 Number 3 May 2009mentioning
confidence: 99%
See 1 more Smart Citation
“…In the eye, this error is affected by the viewing angle, the anterior corneal curvature, and the corneal refractive index. Various mathematical approaches to resolving the true positions of the deep surfaces exist 6,7 and are device and software specific. Because of this dependence on first-surface curvature, this purely optical error may also contribute to artifactual posterior corneal surface changes after refractive surgery.…”
Section: Quantificationmentioning
confidence: 99%