2007
DOI: 10.1109/tia.2007.900494
|View full text |Cite
|
Sign up to set email alerts
|

Observer-Based Estimation of Stator-Winding Faults in Delta-Connected Induction Motors: A Linear Matrix Inequality Approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(16 citation statements)
references
References 16 publications
0
16
0
Order By: Relevance
“…Therefore, the only way to achieve actual information about the fault factor value is its estimation. To achieve this goal, a method based on a stator current observer can be utilized [40,47]. This idea relies on calculation of the error between the estimated and measured stator current.…”
Section: Improvement Of the Drive Performance During Itsc By An Ftc Umentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, the only way to achieve actual information about the fault factor value is its estimation. To achieve this goal, a method based on a stator current observer can be utilized [40,47]. This idea relies on calculation of the error between the estimated and measured stator current.…”
Section: Improvement Of the Drive Performance During Itsc By An Ftc Umentioning
confidence: 99%
“…Nonetheless, other techniques for ITSC effect compensation in IMs have been considered in control schemes with classical (PI or hysteresis) controllers as well. In Reference [39], an extended state observer [40] was used to eliminate a decoupling between flux and torque control paths, caused by an ITSC in the FOC scheme. This method was based on the assumption that accurate estimation of the state variables of a machine during ITSCs enables precise control of the IM and ensures stable operation of the drive.…”
Section: Introductionmentioning
confidence: 99%
“…By substituting Equation (33) (29), equals so ν , is unknown, and it is necessary to calculate the short circuit current, as indicate by (29). Since the homopolar component of stator current i so = 0 in a Y-connected motor winding, from Equations (34), (31) and (27), we can obtain the following expression:…”
Section: Faulty Model In the Stator Fixed Dqo-framementioning
confidence: 99%
“…In this method the neutral connection of the machine must be accessible. An observer has also been designed for delta connected machines [14]. In [15] the pendulous oscillation phenomenon and its behavior under faulty conditions has been studied.…”
Section: Introductionmentioning
confidence: 99%