Numerical optimization on thermal performance characteristics of interior walls based on air-conditioning intermittent running

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 24 publications
2
4
0
Order By: Relevance
“…However, due to the fact that adding the air space ceiling can increase the thermal resistance of floors, the negative impact was gained under Cases 2 and 4. These rules are in line with Meng et al (2018c).…”
Section: Resultssupporting
confidence: 78%
See 3 more Smart Citations
“…However, due to the fact that adding the air space ceiling can increase the thermal resistance of floors, the negative impact was gained under Cases 2 and 4. These rules are in line with Meng et al (2018c).…”
Section: Resultssupporting
confidence: 78%
“…In the other research under the same thermal conditions (Meng et al, 2018a, 2018c), the optimization can lead to reducing the cooling load by 7%–19% and 12.7%–26.1% for the exterior and interior walls, respectively. Compared to the reduced daily cooling load of 47.00%–53.27% through the floor optimization, the floor is affirmed as the most vulnerable spot of the room heat preservation.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Table 1. A summary on the thermal performance analysis on non-transparent envelopes under air-conditioning intermittent operation (Barrios et al, 2012;Hou et al, 2018;Ibrahim et al, 2012;Li et al, 2018;Meng et al, 2018aMeng et al, , 2018bMeng et al, , 2018cRuan et al, 2015;Yan et al, 2015;Yuan et al, 2017;Zhang et al, 2017a) Aimed at this, a common office building was chosen and inner surface heat flows in the studied room were measured under the intermittent different groups of airconditioning in the adjacent rooms. Three typical rooms with the different areas were considered with one and two exterior walls, and combined with envelop areas and heat flow values, the heat transfer capacity through the different envelopes could be gained to analyze the composition characteristic on cooling load formed by non-transparent envelopes of a common office building under air-conditioning intermittent operation.…”
Section: Introductionmentioning
confidence: 99%