2019
DOI: 10.3390/en12112128
|View full text |Cite
|
Sign up to set email alerts
|

Numerical Modeling of Space–Time Characteristics of Plasma Initialization in a Secondary Arc

Abstract: A numerical model based on the finite element simulation software COMSOL was developed to investigate the secondary arc that can limit the success of single-phase auto-reclosure solutions to the single-phase-to-ground fault. Partial differential equations accounting for variation of densities of charge particles (electrons, positive and negative ions) were coupled with Poisson’s equation to consider the effects of space and surface charges on the electric field. An experiment platform was established to verify… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…In figure 5, V in is the external DC voltage, which was set to 15 000 V, and in the external RC series circuit, R and C were set to 120 Ω and 8.1 μF, respectively. In order to make the initial environment universal, the electron density value in the simulation domain is set to 10 13 m −3 with reference to many studies [17,33,34], and the electron density variation during the electrode breakdown process was shown in figure 6.…”
Section: High Voltage Breakdown Process Of Electrodementioning
confidence: 99%
“…In figure 5, V in is the external DC voltage, which was set to 15 000 V, and in the external RC series circuit, R and C were set to 120 Ω and 8.1 μF, respectively. In order to make the initial environment universal, the electron density value in the simulation domain is set to 10 13 m −3 with reference to many studies [17,33,34], and the electron density variation during the electrode breakdown process was shown in figure 6.…”
Section: High Voltage Breakdown Process Of Electrodementioning
confidence: 99%
“…The arc resistance is estimated at 20.7 kΩ. A typical "zero break" phenomenon of arc current is observed [28][29][30][31][32][33].…”
Section: The Electric Characteristics Of Jacob's Ladder Arcmentioning
confidence: 99%
“…The arc resistance is estimated at 20.7 kΩ. A typical "zero break" phenomenon of arc current is observed [28][29][30][31][32][33]. Typical voltage and current waveforms of the arc are shown in Figure 3.…”
Section: The Electric Characteristics Of Jacob's Ladder Arcmentioning
confidence: 99%