2021
DOI: 10.1016/j.ijheatmasstransfer.2021.121091
|View full text |Cite
|
Sign up to set email alerts
|

Numerical investigations on flow boiling heat transfer of ammonia water binary solution (NH3/H2O) in a horizontal microchannel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 46 publications
0
5
0
Order By: Relevance
“…Under this condition, the average heat flux of the chip will reach 5000 kW/m 2 , and the local hot spot heat flux will exceed 10 000 kW/m 2 , 3 . Many classical heat dissipation methods have lost their effects under this condition 4,5 . Eighty‐five degrees Celsius is the stable operating temperature threshold of the commonly used electronic chips 6 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Under this condition, the average heat flux of the chip will reach 5000 kW/m 2 , and the local hot spot heat flux will exceed 10 000 kW/m 2 , 3 . Many classical heat dissipation methods have lost their effects under this condition 4,5 . Eighty‐five degrees Celsius is the stable operating temperature threshold of the commonly used electronic chips 6 .…”
Section: Introductionmentioning
confidence: 99%
“…2,3 Many classical heat dissipation methods have lost their effects under this condition. 4,5 Eighty-five degrees Celsius is the stable operating temperature threshold of the commonly used electronic chips. 6 Too high temperature will lead to a dramatic drop in performance and even cause failure of the chip and the bus motherboard connecting the chip.…”
Section: Introductionmentioning
confidence: 99%
“…However, the designer of MPTL need to master the flow boiling characteristics of the microchannel heat sink so as to prevent pre-mature Critical Heat Flux (CHF) and flow instabilities [3]. To relieve the problems of two phase flow and heat transfer in the microchannels mentioned above, some recent studies have been centered on developing Computational Fluid Dynamics (CFD) approach for prediction of two phase flow pattern, void fraction, pressure drop, heat transfer coefficient and CHF [4][5][6][7][8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…The results showed that the MM was the best model to predict the void fraction compared to the other two models. Yang et al [5] used the VOF model and the modified Lee model [6] to study the two phase flow and heat transfer characteristics for NH 3 /H 2 O mixture in a horizontal two-dimensional single microchannel. The results indicated that at some cases, it was benefit to used NH 3 /H 2 O mixture as an alternative coolant to prevent local drying of electronic components and maintain the temperature within their limits.…”
Section: Introductionmentioning
confidence: 99%
“…Sitar and Golobic [7] found that the use of water-butanol mixtures can postpone the occurrence of dry-out. The study of Yang et al [8] on the flow boiling of NH 3 water mixtures revealed that the improvement of the heat transfer coefficient was caused by the presence of nucleation due to the lower boiling point of the mixtures compared to the pure liquid. These findings show the potential of the application of binary mixtures in the boiling application, and further studies that cover various operating conditions should be conducted.…”
Section: Introductionmentioning
confidence: 99%