2012
DOI: 10.1109/tpel.2011.2175949
|View full text |Cite
|
Sign up to set email alerts
|

Numerical Evaluation of the Short-Circuit Performance of 3.3-kV CIGBT in Field-Stop Technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 8 publications
0
9
0
Order By: Relevance
“…Many references report the short-circuit current behavior for converter-based low-voltage systems [6,7,[18][19][20][21][22][23][24], the behavior of insulated-gate bipolar transistors (IGBTs) in fault conditions [25,26], the protection techniques for low-voltage (high-voltage) DC distribution systems [6,[20][21][22][23][24]27], and DC compact systems (nodes) [6,7]. However, the dynamic performance of the electrical protection system in DC compact systems with solid state circuit breakers (SSCBs), hybrid circuit breakers (HCBs), and protective relays, especially during operation, has not been assessed in any depth.…”
Section: Electrical Protection Of the Multiterminal DC Compact Nodementioning
confidence: 99%
“…Many references report the short-circuit current behavior for converter-based low-voltage systems [6,7,[18][19][20][21][22][23][24], the behavior of insulated-gate bipolar transistors (IGBTs) in fault conditions [25,26], the protection techniques for low-voltage (high-voltage) DC distribution systems [6,[20][21][22][23][24]27], and DC compact systems (nodes) [6,7]. However, the dynamic performance of the electrical protection system in DC compact systems with solid state circuit breakers (SSCBs), hybrid circuit breakers (HCBs), and protective relays, especially during operation, has not been assessed in any depth.…”
Section: Electrical Protection Of the Multiterminal DC Compact Nodementioning
confidence: 99%
“…DC distribution protection system is divided into three protection levels, namely, component level, device level, and system level. The researches of short circuit protection of component and device, such as the IGBT and the converter, have been addressed in many publications [17][18][19][20]. Hence, the protection presented in this paper is primarily focused on system level.…”
Section: Protection Systemmentioning
confidence: 99%
“…The topics of shortcircuit protection of the inverter and the IGBT behavior in a short circuit have been addressed in many publications [4], [5], [6], [7], [8], [9], [10], [11]. Typically, the protection is based on short-circuit detection and converter shutdown (trip) in a short circuit.…”
Section: Introductionmentioning
confidence: 99%