2016 Computing in Cardiology Conference (CinC) 2016
DOI: 10.22489/cinc.2016.078-419
|View full text |Cite
|
Sign up to set email alerts
|

Numerical Analysis of Conduction of the Action Potential Across the Purkinje Fibre:Ventricular Muscle Junction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…One of the important characteristics of a pacemaking cell is its synchronization behavior under an applied load of coupled cells with a variable diffusion coefficient [ 53 55 ]. To investigate this property of the considered pacemaking cells, we set up three variants of the load— n strands (cables) of matching 20 excitable cells coupled to a single pacemaker cell.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the important characteristics of a pacemaking cell is its synchronization behavior under an applied load of coupled cells with a variable diffusion coefficient [ 53 55 ]. To investigate this property of the considered pacemaking cells, we set up three variants of the load— n strands (cables) of matching 20 excitable cells coupled to a single pacemaker cell.…”
Section: Methodsmentioning
confidence: 99%
“…To investigate this property of the considered pacemaking cells, we set up three variants of the load— n strands (cables) of matching 20 excitable cells coupled to a single pacemaker cell. Because the load in a tissue is not limited to an integer value ( n can be non-integer [ 55 ]), apart from the normal case ( n = 1) we considered higher ( n = 2) and lower ( n = 0.5) loads.…”
Section: Methodsmentioning
confidence: 99%
“…Because the load in a tissue is not limited to an integer value (n can be non-integer [46]), apart from normal case (n = 1) we considered higher (n = 2) and lower (n = 0.5) loads.…”
Section: Coupled 1d Pacemaker-excitable Systemsmentioning
confidence: 99%
“…The incremental steps of the parameters were selected individually for each model and varied depending on observed dynamics. When spontaneous oscillation appeared, we determined peak overshoot potential (POP), maximum diastolic potential (MDP), frequency, diastolic interval (DI), and action potential duration (APD) at 90% repolarization for each bifurcation parameter value upon allowing the oscillation activity to stabilize within 20 -50 s. non-integer [55]), apart from the normal case (n = 1) we considered higher (n = 2) and lower (n = 0.5) loads. These load-driving capabilities are essential for real-time simulation systems based on abstracted heart models, where a single pacemaker cell represents a group of ion-channel pacemaker model cells [44,46].…”
Section: Isolated Single Pacemaker Cellsmentioning
confidence: 99%
See 1 more Smart Citation