2023
DOI: 10.1177/15385744231191234
|View full text |Cite
|
Sign up to set email alerts
|

Novel Technique for Intentional Occlusion of Directional Branches During Complex Endovascular Aortic Repair Using Microvascular Plugs

Abstract: Purpose To demonstrate the feasibility and outcomes of using the microvascular plug (MVP) for intentional occlusion of directional branches (DB) during complex endovascular aortic procedures. Case Report Two patients were treated with the off-the-shelf four-branched Zenith t-Branch thoracoabdominal stent-graft (Cook Medical, Bloomington, Ind). In both cases, the renal arteries (on one side in patient #1 and on both sides in patient #2, respectively) were occluded at time of index intervention. Preoperative pla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 18 publications
(20 reference statements)
0
2
0
Order By: Relevance
“…The MVP-7Q (MVP, Medtronic, Minneapolis, MN, USA) has also been used to occlude branches, with promising results in terms of early success and avoiding the use of a further bridging stent-graft, thus reducing overall procedural costs and possibly operating time [47] (Figure 6b). Aside from the economic and technical aspects, the -Alternatively, the "dog bone" technique [46] consists of deploying a balloon-expandable stent-graft inside the branch, sizing it 2 mm larger than the branch itself.…”
Section: Intentional Directional Branch Closure In Complex Aortic Repairmentioning
confidence: 99%
See 1 more Smart Citation
“…The MVP-7Q (MVP, Medtronic, Minneapolis, MN, USA) has also been used to occlude branches, with promising results in terms of early success and avoiding the use of a further bridging stent-graft, thus reducing overall procedural costs and possibly operating time [47] (Figure 6b). Aside from the economic and technical aspects, the -Alternatively, the "dog bone" technique [46] consists of deploying a balloon-expandable stent-graft inside the branch, sizing it 2 mm larger than the branch itself.…”
Section: Intentional Directional Branch Closure In Complex Aortic Repairmentioning
confidence: 99%
“…The MVP-7Q (MVP, Medtronic, Minneapolis, MN, USA) has also been used to occlude branches, with promising results in terms of early success and avoiding the use of a further bridging stent-graft, thus reducing overall procedural costs and possibly operating time [47] (Figure 6b). Aside from the economic and technical aspects, the MVP PTFE membrane design guarantees immediate vessel occlusion, which is of paramount importance in symptomatic/ruptured aneurysms, as opposed to the AVP II design which needs time to achieve complete branch thrombosis.…”
Section: Intentional Directional Branch Closure In Complex Aortic Repairmentioning
confidence: 99%