2019
DOI: 10.1016/j.microc.2019.104043
|View full text |Cite
|
Sign up to set email alerts
|

Novel restricted access material combined to molecularly imprinted polymer for selective magnetic solid-phase extraction of estrogens from human urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 40 publications
(4 citation statements)
references
References 54 publications
0
4
0
Order By: Relevance
“…The bands at 1270 cm −1 and 2980 cm −1 were attributed to the C-O and C-H, respectively. The absorption peak around 3525 cm −1 was related to the N-H stretching vibration of the amino group [30][31][32]. For CPE-MagMIP the band, characteristic of carbonaceous materials, was detected between 2900 cm −1 [33].…”
Section: Ft-ir Characterizationmentioning
confidence: 96%
“…The bands at 1270 cm −1 and 2980 cm −1 were attributed to the C-O and C-H, respectively. The absorption peak around 3525 cm −1 was related to the N-H stretching vibration of the amino group [30][31][32]. For CPE-MagMIP the band, characteristic of carbonaceous materials, was detected between 2900 cm −1 [33].…”
Section: Ft-ir Characterizationmentioning
confidence: 96%
“…Oliveira et al ( 2019a , 2019b ) in 2019 reported two new methods in different papers for successfully determination of estrogens such as estriol (E3) and estrone (E1) from human urine by Restricted Access Mesoporous Molecularly Imprinted Polymer double coated with Hydrophilic Monomer and Bovine Serum Albumin (RA-MMIP-HM-BSA/HPLC–UV) method and ethinylestradiol (EE2) and estradiol (E2) from human urine by Restricted Access Material combined to Molecularly Imprinted Polymer for selective Magnetic Solid-Phase Extraction (RAM-MIP-MSPE/HPLC–UV) method. The first developed method was linear for each hormone in the concentration range of 100–1100 ng mL −1 , with correlation coefficients of 0.9952 and 0.9954 for E3 and E1, respectively and the second improved technique produced linearity for each hormone across the concentration range of 80–1100 ng mL −1 , with correlation coefficients of 0.9954 and 0.9971 for E2 and EE2, respectively.…”
Section: Mip In Bioanalysismentioning
confidence: 99%
“…Unusual variations of free estrogens levels may be related to tumor growth, mainly postmenopausal. Oliveira et al [43] employed a magnetic-RAMIP covered with bovine serum albumin for the detection of estradiol and ethinylestradiol in urine samples. A polymer of methacrylic acid was formed at the surface of magnetic nanoparticles in the presence of estradiol (template).…”
Section: Hormonesmentioning
confidence: 99%