2008
DOI: 10.1016/j.talanta.2008.01.061
|View full text |Cite
|
Sign up to set email alerts
|

Novel PVC membrane-based thoron ion selective electrode and its application: Determination of zirconium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…In Arida (2008) and Gupta, Goyal, and Sharma (2009), the authors describe some examples of the application of electrodes selective to organic reagents for the indirect determination of zirconium, which forms a complex with them. So, a sensor with a membrane containing thoron (4-((2-arsonophenyl)azo)-3-hydroxy-2,7naphthalenedisulfonic acid) was used for determining 1.8•10 −4 -2.6•10 −3 mol•l −1 of zirconium (Arida 2008). A sensor with membrane based on alizarin red S was used for determining 5-28 μg•l −1 zirconium in solutions of alloys (Gupta, Goyal & Sharma, 2009).…”
Section: Shervedani and Bagherzadeh 2009mentioning
confidence: 99%
“…In Arida (2008) and Gupta, Goyal, and Sharma (2009), the authors describe some examples of the application of electrodes selective to organic reagents for the indirect determination of zirconium, which forms a complex with them. So, a sensor with a membrane containing thoron (4-((2-arsonophenyl)azo)-3-hydroxy-2,7naphthalenedisulfonic acid) was used for determining 1.8•10 −4 -2.6•10 −3 mol•l −1 of zirconium (Arida 2008). A sensor with membrane based on alizarin red S was used for determining 5-28 μg•l −1 zirconium in solutions of alloys (Gupta, Goyal & Sharma, 2009).…”
Section: Shervedani and Bagherzadeh 2009mentioning
confidence: 99%
“…For the fabrication of the organic membrane-based microsensor part, a cocktail-coating mixture incorporating the copper(II) ionophore has been utilized. The stock solution of this cocktail-coating mixture was prepared as described elsewhere [24] by mixing thoroughly 33 mg of powdered PVC, 57 mg of o-nitrophenyl octyl ether plasticizer, 3 mg of potassium tetrakis (p-chlorophenyl) borate anion excluder and 7 mg of o-xylylene bis(N,N-diisobutyldithiocarbamate) copper(II) ionophore in a small beaker. The mixture was then completely dissolved in 5 mL THF.…”
Section: Microfabrication Of the Thin-film Organic/inorganic Sensor Hmentioning
confidence: 99%
“…Various analytical techniques used for the determination of zirconium in different matrices include spectrophotometry [6], fluorescence spectrophotometry [7], atomic absorption spectrometry [8], inductively coupled plasma atomic emission spectrometry [9], inductively coupled plasma mass spectrometry [10], isotope dilution mass spectrometry [11], X-ray fluorescence [12], neutron activation analysis [13], proton activation analysis [14], potentiometry [15], kinetic potentiometry [16], polarography [17], stripping voltammetry [18,19], impedimetry [20], and liquid chromatography [21].…”
Section: Introductionmentioning
confidence: 99%