2014
DOI: 10.1016/j.bios.2014.06.021
|View full text |Cite
|
Sign up to set email alerts
|

Novel multiplex fluorescent immunoassays based on quantum dot nanolabels for mycotoxins determination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
52
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 119 publications
(56 citation statements)
references
References 43 publications
(44 reference statements)
0
52
0
Order By: Relevance
“…Immunoassay and aptamer principles have been developed to detect multiple mycotoxins. Wu et al established multiplexed fluorescence resonance energy transfer aptasensor between upconversion nanoparticles and graphene oxide for the simultaneous determination of OTA and FB1 with the LOD of 0.02 ng/mL for OTA and 0.1 ng/mL for FB 1 [101]. Chen et al applied antigen-modified magnetic nanoparticles as biosensor probes and antibody-functionalized improved upconversion nanoparticles as signal probes to develop an ultrasensitive fluorescence biosensor, which showed the LOD of 0.001 ng/mL and detection linear range of 0.001-0.1 ng/mL for AFB 1 and DON in peanut oils [102].…”
Section: Other Biosensor Techniques For Multiplex Mycotoxin Analysismentioning
confidence: 99%
“…Immunoassay and aptamer principles have been developed to detect multiple mycotoxins. Wu et al established multiplexed fluorescence resonance energy transfer aptasensor between upconversion nanoparticles and graphene oxide for the simultaneous determination of OTA and FB1 with the LOD of 0.02 ng/mL for OTA and 0.1 ng/mL for FB 1 [101]. Chen et al applied antigen-modified magnetic nanoparticles as biosensor probes and antibody-functionalized improved upconversion nanoparticles as signal probes to develop an ultrasensitive fluorescence biosensor, which showed the LOD of 0.001 ng/mL and detection linear range of 0.001-0.1 ng/mL for AFB 1 and DON in peanut oils [102].…”
Section: Other Biosensor Techniques For Multiplex Mycotoxin Analysismentioning
confidence: 99%
“…The simultaneous determination of two analytes in a single well by QDs-based FLISA was already described in our previous publication [35]. This approach is exclusively possible if conjugates are labeled with particles that luminescent in different part of spectrum.…”
Section: Development Of the Slqds-based Flisamentioning
confidence: 99%
“…Fig. 3 presents the comparison of the calibration curves for determination of ZEN and AfB1 by QDs- [35] and SLQDs-labeled multiplex FLISA. Due to the higher photoluminescence of SLQDs compared with QDs the lower concentration of specific antibodies was used in the same kind of multiplex based on QDs-detection, and it resulted in the significant increase of the assay sensitivity (Table 1) …”
Section: Development Of the Slqds-based Flisamentioning
confidence: 99%
See 1 more Smart Citation
“…These advantages have been widely applied for the multiplexed simultaneous detection of different targets [2][3][4][5][6][7] .…”
Section: Introductionmentioning
confidence: 99%