2019
DOI: 10.1016/j.microc.2018.10.021
|View full text |Cite
|
Sign up to set email alerts
|

Novel fluorescence labeling reagent 4-(carbazole-9-yl)-benzyl chloroformate and its application in the determination of nitrofuran metabolites compounds in foodstuffs by high performance liquid chromatography with fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 27 publications
0
11
0
Order By: Relevance
“…The requirement of temperature for derivatization in different literature reports was referenced for better comparison. 15 , 18 , 44 Excessive temperature may cause decomposition of the product, so 37, 50, and 60 °C were selected as the screening temperatures for ultrasound-assisted derivatization. To avoid erroneous conclusions about the interaction between the derivatization temperature and time, we tested different temperatures and simultaneously screened the derivatization time.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The requirement of temperature for derivatization in different literature reports was referenced for better comparison. 15 , 18 , 44 Excessive temperature may cause decomposition of the product, so 37, 50, and 60 °C were selected as the screening temperatures for ultrasound-assisted derivatization. To avoid erroneous conclusions about the interaction between the derivatization temperature and time, we tested different temperatures and simultaneously screened the derivatization time.…”
Section: Resultsmentioning
confidence: 99%
“… 13 , 14 At present, the minimum performance limit (MRPL) of these residual compounds in meat products stipulated by the EU is 1.0 μg/kg. 2 , 15 In this context, it is essential to develop a fast and sensitive detection method for NF metabolite compounds for solving food safety problems.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Presently available detection methods for antibiotics include mass spectrometry, high performance liquid chromatography, LC with MS detection, electrochemical analysis and so on . Most of these approaches are expensive apparatus‐dependant, operation‐complicated and time‐consuming.…”
Section: Introductionmentioning
confidence: 99%
“…The use of o‐phthalaldehyde in connection with thiol‐containing compounds (e.g. 3‐mercaptopropionic acid, 2‐mercaptoethanol) has been widely applied to the determination of low concentrations of GABA analogs via FLD analysis . However, thiol‐containing derivatives are unstable.…”
Section: Introductionmentioning
confidence: 99%