2017
DOI: 10.1016/j.medengphy.2017.04.001
|View full text |Cite
|
Sign up to set email alerts
|

Notched K-wire for low thermal damage bone drilling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 18 publications
1
15
0
Order By: Relevance
“…The orbital motion of the rotating K‐wire helped evacuation of bone debris, which carried away portion of heat from the cutting area. Heat reduction mechanism of this drilling technique was similar to the modified K‐wires with notched or fluted cutting tips . Due to the oscillation and vibration nature of the oscillatory mode, shaky drilling was spontaneous even if the surgeon tried to apply constant thrust force on the hand drill.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…The orbital motion of the rotating K‐wire helped evacuation of bone debris, which carried away portion of heat from the cutting area. Heat reduction mechanism of this drilling technique was similar to the modified K‐wires with notched or fluted cutting tips . Due to the oscillation and vibration nature of the oscillatory mode, shaky drilling was spontaneous even if the surgeon tried to apply constant thrust force on the hand drill.…”
Section: Discussionmentioning
confidence: 98%
“…Also, they found that trocar tip K‐wires generated higher temperature than diamond tip ones. Liu et al modified trocar tip K‐wires with notches for debris evacuation and reported reduced bone temperature rise.…”
mentioning
confidence: 99%
“…These shapes facilitate the evacuation performance of bone chips. 119,187 For example, a conventional flute (flute area of 45-55% compared to diameter) is sufficient to remove chips in the general drilling. 171 A parabolic flute provides broader flute space than the conventional flute and, therefore, improves the chip evacuation.…”
Section: Flutementioning
confidence: 99%
“…C) and notches (Fig. D) to improve the debris evacuation and lower bone temperature rise was observed using these modified K‐wires . Learning from surgical twist drills, Piska et al developed a new point configuration called the Medin K‐wire, as shown in Figure E.…”
mentioning
confidence: 99%
“…1D) to improve the debris evacuation and lower bone temperature rise was observed using these modified K-wires. 11,12 Learning from surgical twist drills, Piska et al 13 developed a new point configuration called the Medin K-wire, as shown in Figure 1E. Two short segments of steep flutes were created at the drill tip to change the rake geometry and evacuate the bone debris during drilling.…”
mentioning
confidence: 99%