Normalized methodology for medical infrared imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
41
0
3

Year Published

2011
2011
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 52 publications
(44 citation statements)
references
References 23 publications
(22 reference statements)
0
41
0
3
Order By: Relevance
“…Its principle of image formation is based on the capture and transformation of infrared radiation emitted by the human skin, into images that reflect the microcirculatory dynamics of the skin surface. 1,4,5,7,8,10,11,15,16,[19][20][21][22][23][24][25][26] In spite of various articles having approached the thermographic examination as a promising method in dentistry, 8,[10][11][12]15,16,21,27 in the world literature, up to now, there is no standardization as regards the evaluation of thermograms of the face.…”
Section: Discussionmentioning
confidence: 99%
“…Its principle of image formation is based on the capture and transformation of infrared radiation emitted by the human skin, into images that reflect the microcirculatory dynamics of the skin surface. 1,4,5,7,8,10,11,15,16,[19][20][21][22][23][24][25][26] In spite of various articles having approached the thermographic examination as a promising method in dentistry, 8,[10][11][12]15,16,21,27 in the world literature, up to now, there is no standardization as regards the evaluation of thermograms of the face.…”
Section: Discussionmentioning
confidence: 99%
“…It is worthwhile to mention that in most studies the infrared image analysis is subjective, that is, the location for the evaluation of the muscle temperature is randomly determined 6,8,14,16,28 , while others studies make no reference to the way the analysis was carried out 5,29,30 . Furthermore, no standardization of specific areas for image analysis was found in other studies that measure facial temperature 31,32 .…”
Section: Discussionmentioning
confidence: 99%
“…This thermometer measures temperature values of the eardrum and the surrounding tissues, the location most frequently indicated for measuring body temperature owing to its proximity to the hypothalamus and the perfusion of the arterial labyrinth. 17 For precise evaluation of the ROIs, the thermographs ( Figure 2) were superimposed on the digital photographs using dedicated software (Reporter ® v. 8.5-SP3 Professional Edition and QuickReport ® v. 1.2; FLIR Systems Inc., Wilsonville, OR). The standardized reference points of the superimposition were midpoint of the median sagittal plane between the chin and the hyoid bone, the lowest portion of the earlobe and the apex of the nasal pyramid.…”
Section: Measurement Proceduresmentioning
confidence: 99%
“…The standardized reference points of the superimposition were midpoint of the median sagittal plane between the chin and the hyoid bone, the lowest portion of the earlobe and the apex of the nasal pyramid. The mean absolute temperatures (T) were averaged according to the landmarks (ROIs) recorded on photographic images, and the normalized temperature (u) 17 of each ROI was calculated individually. Interpretation of the infrared camera reading was performed using a dimensionless temperature (u), which combines the measured local temperature with the body (T b ) and ambient temperatures (T ' ), according to the following equation:…”
Section: Measurement Proceduresmentioning
confidence: 99%