2017
DOI: 10.1186/s13321-017-0197-z
|View full text |Cite
|
Sign up to set email alerts
|

Nontargeted homologue series extraction from hyphenated high resolution mass spectrometry data

Abstract: Background A large proportion of polar anthropogenic compounds routinely released into the environment comprises homologue series, i.e., sets of chemicals differing in a repeating chemical unit. Using analytical techniques such as liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS), these compounds are readily measurable as signal sets with characteristic differences in mass and typically retention time. However, and despite such distinct characteristics, no computational approach for … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
50
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(52 citation statements)
references
References 45 publications
0
50
0
Order By: Relevance
“…Unidentified masses were tested for the presence of 37 Cl and 37 Cl 2 isotopes with the pattern.search() function in the R package nontarget 46 with retention time tolerance of ± 10 s and mass accuracy of ± 5 ppm.…”
Section: Methodsmentioning
confidence: 99%
“…Unidentified masses were tested for the presence of 37 Cl and 37 Cl 2 isotopes with the pattern.search() function in the R package nontarget 46 with retention time tolerance of ± 10 s and mass accuracy of ± 5 ppm.…”
Section: Methodsmentioning
confidence: 99%
“…N,34 S,37 Cl and 81 Br) with a rule-based algorithm. Homologue series detection[35] was carried out for four or more consecutive mass differences corresponding to CH 2 , CH 2 O, C 2 H 4 O, C 3 H 6 O, C 2 H 6 SiO, CF 2 and C 2 H 4 units for singly and doubly charged ions. Peaks were finally grouped into components, i.e., the monoisotopic peak and its associated isotope or adduct peaks representing an individual chemical compound.…”
mentioning
confidence: 99%
“…PFAS compounds have negative mass defects ( Figure 6) due to their preponderance of fluorine atoms, and polyfluorinated compounds have positive, but substantially smaller mass defects than homologous organic materials 31,34 . A second method filtering step is to identify homologous series containing repeating units common to PFAS species, such as CF 2 or CF 2 O. Identifying these can be done using Kendrick Mass defect plots 17,36 , or software packages such as R's nontarget package 35 (Figure 7).…”
Section: Representative Resultsmentioning
confidence: 99%