2010
DOI: 10.1089/neu.2010.1388
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive Monitoring of Cerebrovascular Reactivity with Near Infrared Spectroscopy in Head-Injured Patients

Abstract: Monitoring of cerebrovascular pressure reactivity (PRx) has diagnostic and prognostic value in head-injured patients, but requires invasive monitoring of intracranial pressure (ICP). Near infrared spectroscopy (NIRS) is a noninvasive method that is suitable for continuous detection of cerebral blood volume changes. We compared a NIRS-based index of cerebrovascular reactivity, called total hemoglobin reactivity (THx), against standard measurements of PRx in a prospective observational study. Forty patients with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
127
0
3

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 143 publications
(135 citation statements)
references
References 23 publications
5
127
0
3
Order By: Relevance
“…Functional MRI has shown NIRS measurement to be consistent with changes in deoxyhemoglobin concentration and regional cerebral blood volume [74]. The CBF autoregulation can be assessed using NIRS [75] and an NIRS-based autoregulation index, derived from ICP and blood pressure waveforms, has been developed [76]. Despite these validation studies, NIRS remains fundamentally limited in its application, since a small sample volume of the frontal cortex (1.5 cm 3 at a depth of 1.5 cm) is used to represent global cerebral perfusion.…”
Section: Principles Of Cerebral Oximetrymentioning
confidence: 99%
“…Functional MRI has shown NIRS measurement to be consistent with changes in deoxyhemoglobin concentration and regional cerebral blood volume [74]. The CBF autoregulation can be assessed using NIRS [75] and an NIRS-based autoregulation index, derived from ICP and blood pressure waveforms, has been developed [76]. Despite these validation studies, NIRS remains fundamentally limited in its application, since a small sample volume of the frontal cortex (1.5 cm 3 at a depth of 1.5 cm) is used to represent global cerebral perfusion.…”
Section: Principles Of Cerebral Oximetrymentioning
confidence: 99%
“…Some studies indicate a correlation between data from NIRS and TCD and suggest that NIRS may be more sensitive than TCD for detecting compromised cerebral oxygenation. 37,38 In patients with a new focal neurological deficit, NIRS detected decreased cerebral oxygenation in the affected region and a rise in oxygenation after treatment with an inotrope. 39,40 However, others have found no such correlation.…”
Section: Jugular Bulb Oximetrymentioning
confidence: 99%
“…-PRx can be estimated noninvasively using near infrared spectroscopy. Total hemoglobin or hemoglobin volume correlated with ABP (with the same time averaging and correlating scales as for PRx), producing noninvasive equivalents of PRx: THx and HVx [16,20]. They allow calculation of 'optimal ABP,' so far used in cardiac surgery [2] and brain protection of preterm neonates [8].…”
mentioning
confidence: 99%