2007
DOI: 10.1007/s00134-007-0640-0
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive cardiac output monitoring (NICOM): a clinical validation

Abstract: Cardiac output measured by NICOM had most often acceptable accuracy, precision, and responsiveness in a wide range of circulatory situations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
201
0
8

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 282 publications
(211 citation statements)
references
References 19 publications
2
201
0
8
Order By: Relevance
“…Transthoracic bioreactance is a recently introduced technology that allows for the noninvasive measurement of CO (NICOM1; Cheetah Medical Inc., Portland, OR, USA) [5,6]. The bioreactance signal is determined by measuring blood flow-dependent changes in the phase shifts between an oscillating electrical current applied across the thorax and the resulting voltage signal.…”
Section: Introductionmentioning
confidence: 99%
“…Transthoracic bioreactance is a recently introduced technology that allows for the noninvasive measurement of CO (NICOM1; Cheetah Medical Inc., Portland, OR, USA) [5,6]. The bioreactance signal is determined by measuring blood flow-dependent changes in the phase shifts between an oscillating electrical current applied across the thorax and the resulting voltage signal.…”
Section: Introductionmentioning
confidence: 99%
“…Reproducibility of haemodynamic measures at rest and their response to stress in heart failure using a non‐invasive gas rebreathing technology has been previously reported 19. In post‐cardiac surgery patients, the bioreactance method was validated against thermodilution with a strong relationship reported between the two methods 24. Myers et al .…”
Section: Discussionmentioning
confidence: 89%
“…These frequency changes correlate well with instantaneous changes in blood volume and blood flow in the aorta. Bioreactance was validated in various nonpregnant populations which manifested hemodynamic instability, [19][20][21] and it has been shown to produce hemodynamic profiles in the pregnant population consistent with other more invasive forms of monitoring. 22 Noninvasive CO monitoring provides continuous HR data, performs noninvasive blood pressure measurements at one-minute intervals, and records one-minute running averages of CO, stroke volume, SVV, and TPR.…”
Section: Discussionmentioning
confidence: 97%
“…22 Noninvasive CO monitoring provides continuous HR data, performs noninvasive blood pressure measurements at one-minute intervals, and records one-minute running averages of CO, stroke volume, SVV, and TPR. Noninvasive CO monitoring appears to report directional changes in CO well, 19,20 but the absolute values in pregnancy are not well validated. Therefore, in our view, the trends seen in this report may be of greater importance than the absolute CO values.…”
Section: Discussionmentioning
confidence: 99%