Non-Visible Defect Analysis of OTP Device

Abstract: Several product lots were found to suffer from data retention failures in OTP (one time program) devices. PFA (physical failure analysis) was performed on these devices, but nothing abnormal was observed. Cross-sectional TEM (transmission electron microscopy) revealed no physical defects or abnormal CDs (critical dimensions). In order to isolate the failed layer or location, electrical analysis was conducted. Several electrical simulation experiments, designed to test the data retention properties of OTP devic… Show more