Non-touch fittings in hospitals: a possible source of Pseudomonas aeruginosa and Legionella spp.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

3
51
0
5

Year Published

2006
2006
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(59 citation statements)
references
References 10 publications
3
51
0
5
Order By: Relevance
“…Specific localized problems that can affect Legionella colonization of fixtures include moderate temperature, presence of mixing valves in electronic/sensor type fixtures, and lack of use. [11][12][13] Our experience indicates that increasing the recirculating hot water temperature to 1408F will restrict Legionella growth in the recirculating line; however, Legionella will be unaffected at the distal outlets, and these outlets will remain extensively colonized. Therefore, relying solely on the testing of the recirculating hot water line for assessing the status of Legionella colonization within a complex water distribution system may be misleading.…”
Section: Where To Sample-distal Outlets Versus Centralized Hot Water mentioning
confidence: 98%
“…Specific localized problems that can affect Legionella colonization of fixtures include moderate temperature, presence of mixing valves in electronic/sensor type fixtures, and lack of use. [11][12][13] Our experience indicates that increasing the recirculating hot water temperature to 1408F will restrict Legionella growth in the recirculating line; however, Legionella will be unaffected at the distal outlets, and these outlets will remain extensively colonized. Therefore, relying solely on the testing of the recirculating hot water line for assessing the status of Legionella colonization within a complex water distribution system may be misleading.…”
Section: Where To Sample-distal Outlets Versus Centralized Hot Water mentioning
confidence: 98%
“…1 Several of these outbreaks have been directly or indirectly linked to water distribution systems. [2][3][4][5][6][7][8][9][10][11][12][13][14] In ICUs, 30%-50% of P. aeruginosa infections have been associated with water. 15 A multicentric prospective study recently established tap contamination in patient rooms as an important environmental risk factor for P. aeruginosa acquisition.…”
mentioning
confidence: 99%
“…16 Several factors promote water contamination, including the type of faucet, 9,17,18 the presence and type of aerator on the faucet, 19 the volume of mixed hot and cold water, 17 the alignment of the sink drain, 20 construction or renovation settings, and ICU vs non-ICU settings. 3,20 Once contaminated, eradication of P. aeruginosa in the water system is challenging and often results in replacing related devices 5,[7][8][9][10][11][12]14 or installing point-of-use 0.2-μm filters. 4,13,14 Although cultivation is the reference method, it may not reveal background contamination that may flare up when the environment becomes favorable for growth and culturability.…”
mentioning
confidence: 99%
“…Auch elektronisch gesteuerte berührungs-lose Wasserarmaturen sind als mögliche Quelle für P. aeruginosa und Legionellen beschrieben worden [263] [274].…”
Section: Sanitärbereichunclassified