Post-Outbreak Investigation of Pseudomonas aeruginosa Faucet Contamination by Quantitative Polymerase Chain Reaction and Environmental Factors Affecting Positivity

Abstract: OBJECTIVETo perform a post-outbreak prospective study of the Pseudomonas aeruginosa contamination at the faucets (water, aerator and drain) by culture and quantitative polymerase chain reaction (qPCR) and to assess environmental factors influencing occurrenceSETTINGA 450-bed pediatric university hospital in Montreal, CanadaMETHODSWater, aerator swab, and drain swab samples were collected from faucets and analyzed by culture and qPCR for the post-outbreak investigation. Water microbial and physicochemical param… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 39 publications
(32 citation statements)
references
References 29 publications
(79 reference statements)
1
31
0
Order By: Relevance
“…Contaminated sinks or faucets have been described as sources for P. aeruginosa outbreaks in the past [1, 2, 4, 11, 19, 20]. In many outbreaks, contaminated washbasins served as continuous sources.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Contaminated sinks or faucets have been described as sources for P. aeruginosa outbreaks in the past [1, 2, 4, 11, 19, 20]. In many outbreaks, contaminated washbasins served as continuous sources.…”
Section: Discussionmentioning
confidence: 99%
“…This is supported by the finding that antimicrobial therapy prior to an ICU stay increases the risk for colonization with MDR P. aeruginosa [8, 15] . Once the organisms are introduced into an ICU, they can cause outbreaks that are often associated with sinks or faucets as a continuous source of further spread [1, 2, 11, 19, 20]. However, the most likely transmission route is direct person-to-person contact [10].…”
Section: Introductionmentioning
confidence: 99%
“…It has been extensively applied for OPPP monitoring for both environmental and clinical samples (Adrados et al, 2011; Ahmed et al, 2014; Bedard et al, 2015; Behets et al, 2007a; Beumer et al, 2010; Bonetta et al, 2010; Madarova et al, 2010; Morio et al, 2008; Qin et al, 2003; Radomski et al, 2010). Given its consistency and quantitative capabilities, q-PCR has potential to be accepted as a standard method for pathogen monitoring.…”
Section: Detection Methodsmentioning
confidence: 99%
“…Head-to-head comparison of OPPP detection by q-PCR and culture of water and biofilm samples has been the subject of multiple studies (Table 2), with the general trend being higher detection frequency and cell numbers by q-PCR (e.g., Legionella (Wang et al, 2012; Wellinghausen et al, 2001; Wullings et al, 2011), mycobacteria (Hussein et al, 2009; Radomski et al, 2013), P. aeruginosa (Bedard et al, 2015), N. fowleri (Behets et al, 2007a)). This phenomenon is likely associated with higher sensitivity and lower detection limit of q-PCR.…”
Section: Detection Methodsmentioning
confidence: 99%
“…When sink basin drainage was immediately underneath the faucet, environmental contamination occurred regardless of the speed of the drainage but was 8 times greater with slow drainage. The importance of sink basin design was supported by a separate study, where sinks with faucets aligned behind a drain had a higher rate of contamination by P. aeruginosa compared to drains aligned directly with, in front of, or to the side of the faucet [33]. Similarly, slower drainage was found to be associated with a higher microbiological burden and drain positivity for contamination [33].…”
Section: Non-outbreak Reportsmentioning