2016
DOI: 10.1016/j.jdiacomp.2015.07.019
|View full text |Cite
|
Sign up to set email alerts
|

Non-invasive vascular assessment in the foot with diabetes: sensitivity and specificity of the ankle brachial index, toe brachial index and continuous wave Doppler for detecting peripheral arterial disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
100
2
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 74 publications
(108 citation statements)
references
References 28 publications
3
100
2
2
Order By: Relevance
“…6 The similar performance of this test in the diabetes group compared to the no diabetes group may be due to the fact that CWD appears to have higher sensitivity in more severe disease groups. This is typically found more frequently in diabetes populations, 3,6 and this was the case in this diabetes cohort in this study, where the majority of PAD was occlusive.…”
Section: Discussionsupporting
confidence: 65%
See 2 more Smart Citations
“…6 The similar performance of this test in the diabetes group compared to the no diabetes group may be due to the fact that CWD appears to have higher sensitivity in more severe disease groups. This is typically found more frequently in diabetes populations, 3,6 and this was the case in this diabetes cohort in this study, where the majority of PAD was occlusive.…”
Section: Discussionsupporting
confidence: 65%
“…These results indicate that CWD is unlikely to result in a false diagnosis of PAD, consistent with previous findings. 3,6 Negative likelihood ratios approximately 0.20 in both groups indicate that a negative CWD result is associated with a moderate decrease in probability of PAD. 16 Investigation of the sensitivity of CWD for PAD by severity and location of disease identified several potential limitations of this form of assessment.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…As these patients would be the patient population that may benefit from a more accurate measurement. The other limitation of this study is, to prove ABI-d is comparable or reliable measure to ABI-s we could compare the automated boso ABI machine measurement to a mercury sphygmomanometer and continuous Doppler device [25]. This would have prolonged the time of the examination and the major aim of the study was to obtain the ABI-s and ABI-d values for comparison between all the groups and further studies are need to explore this issue.…”
Section: Discussionmentioning
confidence: 99%
“…A Doppler-hullám spektrumelemzése a perifériás érbe-tegség kimutatásának hatékony eszköze a cukorbeteg populációban [23].…”
Section: áBra Artériás Doppler-görbék Típusaiunclassified